Installation
512685
12
Exhaust Direction
The dryer can be exhausted to the outdoors through the 
back, left, right or bottom of the dryer. EXCEPTION: 
Gas dryers cannot be vented out the left side 
because of the burner housing.
Dryer is shipped from factory ready for rear exhaust.
Exhausting the dryer through sides or bottom can be 
accomplished by installing a Directional Exhaust Kit, 
528P3, available as optional equipment at extra cost. 
Exhaust System
For best drying results, recommended maximum 
length of exhaust system is shown in Table 1.
To prevent backdraft when dryer is not in operation, 
outer end of exhaust pipe must have a weather hood 
with hinged dampers (obtain locally).
NOTE:  Weather hood should be installed at least 
12 inches (30.5 cm) above the ground. Larger 
clearances may be necessary for installations where 
heavy snowfall can occur.
Table 1 
Number of 
90° Elbows
Weather Hood Type
Recommended
Use Only for Short Run installations
Maximum length of 4 in. (10.2 cm) diameter rigid metal duct.
0
65 feet (19.8 m)
55 feet (16.8 m)
1
55 feet (16.8 m)
47 feet (14.3 m)
2
47 feet (14.3 m)
41 feet (12.5 m)
3
36 feet (11.0 m)
30 feet (9.1 m)
4
28 feet (8.5 m)
22 feet (6.7 m)
Maximum length of 4 in. (10.2 cm) diameter flexible metal duct.
0
45 feet (13.7 m)
35 feet (10.7 m)
1
35 feet (10.7 m)
27 feet (8.2 m)
2
30 feet (9.1 m)
21 feet (6.4 m)
3
25 feet (7.6 m)
17 feet (5.2 m)
4
20 feet (6.1 m)
15 feet (4.5 m)
NOTE: Deduct 6 feet (1.8 m) for each additional elbow.
4 in.
(10.2 cm)
4 in.
(10.2 cm)
D673I
D802I
2-1/2 in.
(6.35 cm)