GAS REQUIREMENTS
IMPORTANT: Any product revisions or conversions 
must be made by the Manufacturer’s Authorized 
Dealers, Distributors or local service personnel.
IMPORTANT: The installation must comply with 
local codes or, in the absence of local codes:
with the latest edition of the “National Fuel 
Gas Code”, ANSI Z223.1 in the U.S.A.
with CAN1-B149.1 or CAN1-B149.2 in 
Canada
and Australian Gas Association/Australian 
L.P. Gas Association requirements in Australia
The size of gas service pipe is dependent upon many 
variables (lengths, tees, etc.).  Specific pipe size 
information should be obtained from the gas supplier.  
Refer to Table 2 for general pipe size.
A dirt and water vapor pipe trap must be furnished and 
installed by customer. Refer to Figure 6.
It is important that equal pressure be maintained at all 
tumbler gas connections.  This can best be done by 
installing a one inch (2.54 cm) pipe gas loop. Refer to  
Figure 7
.
NATURAL GAS service must be supplied at 6-1/2  ± 
1-1/2 inch water column pressure (1.62 ± .37 kPa).
L.P. GAS service must be supplied at 11 ± .3 inch water 
column pressure (2.74 ± .07 kPa).
To reduce the risk of fire or explosion, DO 
NOT CONNECT THE GAS LINE TO THE 
TUMBLER IF THE GAS SERVICE IS NOT 
THE SAME AS THAT SPECIFIED ON THE 
TUMBLER SERIAL PLATE! It will first be 
necessary to convert the gas burner 
orifice and gas valve. Appropriate 
conversion kits are available.
W060
WARNING
The tumbler and its individual shut-off 
valve must be disconnected from the gas 
supply piping system during any pressure 
testing of that system at test pressures in 
excess of 1/2 psig (3.45 kPa).
The tumbler must be isolated from the gas 
supply piping system by closing its 
individual manual shut-off valve during 
any pressure testing of the gas supply 
piping system at test pressure equal to or 
less than 1/2 psig (3.45 kPa).
W061
WARNING
To reduce the risk of fire or explosion, if 
the tumbler is to be connected to 
Liquefied Petroleum (L.P.) gas, a vent to 
the outdoors must be provided in the 
room where the tumbler is installed.
W062
WARNING