Alliance Laundry Systems 000 BTU User Manual

Page of 144
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
60
M414545
SECURITY LOCK-OUT
The programming pads can be “locked out” so operators 
cannot change cycles on their own.  When lock-out is 
used, the operator can use only the factory-set Automatic 
cycles and the one Custom cycle allowed per Select pad.  
Before using lock-out, create all desired Custom cycles.
To lock-out, hold SIGNAL pad and press MORE in the 
idle mode.
To unlock, hold SIGNAL pad and press LESS in the idle 
mode.
TEMPERATURE ADJUSTMENT
Selecting a fabric type selects a preset ideal temperature 
for that fabric.  Lower temperatures may be needed for 
small loads or when airflow through the tumbler is less 
than ideal due to inadequate make-up air or exhaust 
ducting.  
Whenever the control is on, but not in NO HEAT, COOL 
DOWN or LOAD READY, pressing the TEMP pad 
displays the three digits of the set temperature.  Use the 
MORE or LESS pad to increase or decrease the 
temperature. 
To select between Fahrenheit and Celsius display, hold in 
the TEMP DISPLAY pad while pressing the TEMP pad.
Temperature Setting Ranges
Table 11
NOTE:  Temperature can be set from 80°F (27°C) to 
180°F (82°C) in the Special Cycle and Special Time 
options only.
To include an adjusted temperature in a Custom cycle, 
simply adjust temperature before pressing CUSTOM.
SHOW MODE
This mode will show all LED’s and light up entire display 
while deactivating all pads. This mode allows loading 
door to be opened and closed. To enter this mode, the 
control must first be in the idle mode. Hold the START 
pad and press the SAVE CUSTOM pad. To exit Show 
Mode, hold the START pad and press the SAVE 
CUSTOM pad.
TEMPERATURE SENSOR
To test the temperature sensor, hold COOL DOWN  pad 
and press the TEMP pad in the idle mode. This will show 
the temperature detected by the control.
“SH” displays and signal sounds if the temperature 
sensor is shorted or sensor temperature is over 200°F 
(93°C). Press the STOP/RESET pad twice within 3 
seconds and allow the tumbler to cool, then press an ON/
SELECT pad.  If “SH” still displays, call for service.
“OP” displays and signal sounds 3 minutes after the 
tumbler is started if the temperature sensor is faulty or if 
a temperature below 24°F (-4.4°C) is detected.  If dryer 
temperature is above 24°F (-4.4°C), call for service.
NOTE: To display the software revision level, hold 
the AUTO pad and press the TIME pad while the 
control is in idle mode.
Fabric 
Selection
Maximum 
Preset Temp
Minimum 
Temp
COTTONS
180° F, 82° C
160° F, 71° C
PERM PRESS
160° F, 71° C
140° F, 60° C
MIXED
140° F, 60° C
120° F, 49° C
DELICATES
120° F, 49° C
100° F, 38° C