Heat Source Check . . .
Electric Dryers
Close the loading door and start the dryer in a heat 
setting (refer to the Operating Instructions supplied 
with the dryer). After the dryer has operated for three 
minutes, the exhaust air or exhaust pipe should be 
warm.
Gas Dryers
To view the burner flame, remove the lower front panel 
of the dryer.
Close the loading door, start the dryer in a heat setting 
(refer to the Operating Instructions supplied with the 
dryer); the dryer will start, the igniter will glow red and 
the main burner will ignite. 
IMPORTANT:  If all air is not purged out of gas 
line, gas igniter may go off before gas is ignited. If 
this happens, after approximately two minutes 
igniter will again attempt gas ignition.
After the dryer has operated for approximately five 
minutes, observe burner flame through lower front 
panel. Adjust the air shutter to obtain a soft, uniform 
blue flame. (A lazy, yellow tipped flame indicates lack 
of air. A harsh, roaring, very blue flame indicates too 
much air.) Adjust the air shutter as follows:
a. Loosen the air shutter lockscrew.
b. Turn the air shutter to the left to get a luminous 
yellow-tipped flame, then turn it back slowly to the 
right to obtain a steady, soft blue flame.
c. After the air shutter is adjusted for proper flame, 
tighten the air shutter lockscrew securely.
d. Reinstall the lower front panel.
After the dryer has operated for approximately three 
minutes, exhaust air or exhaust pipe should be warm.
For personal safety, lower front panel must 
be in place during normal operation.
W046
WARNING
D316IE3A
AIR SHUTTER
LOCKSCREW
AIR
SHUTTER
1/8" (3.1 mm) PIPE PLUG 
(For checking
manifold pressure)
APPLIANCE
MAIN GAS
VALVE