Heat Source Check
Electric Dryers
Metered Models
Set the proper FABRIC SELECTOR switch at 
NORMAL. Place coins in the slide and carefully push 
slide in as far as possible. IN USE light will come on 
indicating the dryer is ready to operate. Close the 
loading door and press the PUSH-TO-START button 
firmly to start the dryer. After the dryer has operated 
for three minutes, the exhaust air or exhaust pipe 
should be warm.
Nonmetered Models
Set FABRIC SELECTOR switch at NORMAL and 
turn timer knob to 50. Close the loading door and press 
the PUSH-TO-START button. IN USE light will 
come on indicating start of cycle. After the dryer has 
operated for three minutes, the exhaust air or exhaust 
pipe should be warm.
Gas Dryers
During the gas heat check, observe the burner flame. 
The flame can be viewed by removing the lower front 
panel of the dryer.
Metered Models
Set FABRIC SELECTOR switch at NORMAL. Place 
coins in the slide and carefully push slide in as far as 
possible. IN USE light will come on indicating the 
dryer is ready to operate. Close the loading door and 
press the PUSH-TO-START button firmly. The dryer 
will start, the igniter will glow red and the main burner 
will ignite. 
Nonmetered Models
Set FABRIC SELECTOR switch at NORMAL and 
turn timer knob to 50. Close the loading door and press 
the PUSH-TO-START button. IN USE light will 
come on indicating start of cycle, igniter will glow red 
and main burner will ignite.
IMPORTANT: If all air is not purged out of the 
gas line, the gas igniter may go off before the gas is 
ignited. If this happens, after approximately two 
minutes the igniter will again attempt gas ignition.