Alliance Laundry Systems TMB1276C User Manual

Page of 44
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
UniLinc Identification
9
70444801
End of Cycle Mode
The control enters End of Cycle Mode after the cool 
down segment is finished. The display will show a 
graphic prompting the user to open the loading door. If 
the door has not been opened or a keypad has not been 
pressed after two minutes, the machine will enter 
Extended Tumble Mode. This mode is exited when the 
door is opened or a
or
keypad is pressed. 
The control will then return to Idle Mode.
Extended Tumble Mode
The Extended Tumble Mode has two portions. The 
Anti-Wrinkle Tumble is entered two minutes after the 
cycle has ended if the door is not opened. The cylinder 
will tumble for 30 seconds every two minutes for up to 
one hour.
If the door hasn’t been opened and no keys have been 
pressed one hour after the Anti-Wrinkle Tumble has 
ended, the control increments the Anti-Wrinkle Time 
Exceeded audit counter and enters Delayed Tumble. 
The cylinder will tumble for two minutes every 60 
minutes for up to 18 hours.
Reversing Mode (reversing models only)
Models equipped with the reversing feature will rotate 
in the forward direction, pause, rotate in the reverse 
direction and then pause for programmable times and 
segments of the cycle. Factory default reversing rotate 
time is 120 seconds and reversing stop time is 6 
seconds for all cycles with reversing enabled.
Entering Diagnostic Mode From Idle Mode
When entered from the Idle Mode, the control will be 
running a test selected by the user via keypad presses 
or communication with a device. The diagnostic tests 
available from the Idle Mode are the Test Cycle and 
Inputs Outputs Menus.