Alliance Laundry Systems TMB1276C User Manual

Page of 44
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Global Setup
29
70444801
Temperature Menu
The Temperatures Menu allows the user to set global 
temperatures for High, Medium, Low, Very Low and 
what unit of measure to display them in. These 
temperature ranges are restricted to those allowed by 
Auto-Dry configurations for a given machine capacity.
Press
and
keypads to move the highlighted 
box through the different items in the menu. Once the 
item is highlighted, press the
and
keypads 
to change the values.
Press the
or
keypad to jump to the Save 
Changes Menu.
Use
or
to move highlighted box to “Yes” 
or “No”.
Press the
keypad to return to Global Setup 
Menu. If no changes were made, press the
 
or
keypad to return to Global Setup Menu.
Reverse Cylinder Menu (if 
equipped)
The Reverse Cylinder Menu allows the user to set the 
rotate and stop time for Reverse Cylinder action and 
cycle specific rotate time, stop time and Advanced 
Reversing. Rotate and Stop Times valid for a heat 
cycle are those available through global Reverse 
Cylinder parameters. If Advance Reversing is enabled, 
the user will be able to view and edit cycle specific 
reversing parameters within Cycle Programming. 
Refer to Figure 24.
The
and
keypads are used to move the 
highlighted box through the different items in the 
Reverse Cylinder Menu. Once the item is highlighted, 
the value can be changed by using the
and 
keypads. Pressing the
or
 keypad 
will jump to the Save Changes Menu. Use
 
or
to move highlighted box to “Yes” or “No”. 
Press the
keypad to return to Global Setup menu. 
If no changes were made, press the
or
 
keypad to return to Global Setup Menu.
TMB1361R
Figure 34 
Temperatures
190
High (H)
160
Medium (M)
140
Low (L)
Units
120
Very Low (VL)
F
°
F
°
F
°
F
°
F
°
TMB1320R
Figure 35 
Rotate Time
Stop Time
Advanced Reversing
Reverse Cylinder
6
No
S
S
120