Diagnostics
70444801
34
Inputs Outputs Menu
When the Inputs Outputs Menu is accessed through 
the Diagnostic Menu, the user can manually turn on 
outputs. The user can scroll through the outputs using 
any of the arrow keys, the cursor is indicated by 
flashing the active output on the screen. The user must 
“setup” the outputs to be turned on. The
keypad 
is used to select individual outputs to be turned on or 
off. After the
keypad is pressed the control will 
turn the selected outputs on and display the text 
“RUNNING”. The outputs cannot be selected until 
the
keypad is pressed. The text “RUNNING” is 
no longer displayed. The screen will still show the 
selected outputs on the screen and the user can again 
select outputs to be turned on or off. If the
or 
keypad is pressed at any time during this test, 
the control will turn off all outputs if the test is running 
or return to the previous screen if the test is not 
running.
If the Inputs Outputs Menu is accessed through the 
Run Diagnostic Menu (pressing the
keypad 
during a running cycle) the menu shows only what is 
turned on and off as the cycle runs. Refer to Figure 43.
Abbreviations for the Inputs and Outputs are defined 
in the following table:
Table 4 
TMB1425R
Figure 43 
Inputs Outputs
Outputs:
Intputs:
RPM:25
Moisture:30%
DM
FM FW
RV
HT
EA IR
DR LD AFS FCRS FCLS CL SL1 SL2
IL
RS
DIP1
DIP2 DIP3 DIP4 DIP5 DIP6
DIP7
DIP8
30:29
Temp:180 F
Inputs
DR
Loading Door
LD
Lint Door
AFS
Airflow Switch
FCRS
Fan Motor Contactor Switch
FCLS
Fan Motor Centrifugal Switch
CL
Cabinet High Limit
SL1
Store 1 High Limit
SL2
Store 2 High Limit
IL
Ignition Lockout
RS
Rotation Sensor
DIP1
Dip Switch 1
DIP2
Dip Switch 2
DIP3
Dip Switch 3
DIP4
Dip Switch 4
DIP5
Dip Switch 5
DIP6
Dip Switch 6
DIP7
Dip Switch 7
DIP8
Dip Switch 8
Temp
Temperature
RPM
Rotations per Minute
Moisture
Moisture Level
Outputs
DM
Damper Motor
FM
Fan Motor
FW
Forward Contactor
RV
Reverse Contactor
HT
Heater
EA
External Alarm
IR
Ignition Reset