Alliance Laundry Systems TMB1276C User Manual

Page of 44
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Preliminary Information
70444801
6
IR Communications Menu
The IR Communications Menu displays while the 
control is communicating with a PDA. The control 
will jump back to the previous page when the 
communication is complete. 
IR Communications Error Menu
The IR Communications Error Menu displays after the 
control had an error communicating with a PDA. The 
control will return to previous page after 3 seconds. 
Restore to Factory Defaults 
When the user selects Restore All Cycles And Global 
Settings To Factory-Defaults, the control resets all of 
the default values. The control also resets Machine 
Cycles #1 through #41. The control will also reset the 
following to factory-defaults:
Default Global Settings
Language = English
Ignition Retries = 3 
Temperature Units = Fahrenheit (°F)
High (H) Temperature = 190 (°F)
Medium (M) Temperature = 160 (°F)
Low (L) Temperature = 140 (°F)
Very Low (VL) Temperature = 120 (°F)
Cool Down Temperature = 100 (°F)
Cool Down Time = 2 (minutes)
Rapid Advance = Disabled
Multi-Segment Cycles = Disabled
LCD Backlight ON/OFF = On
Banner # 1 = Blank
Banner # 2 = Blank
Daylight Saving = Enabled
Key Pad Audio = Enabled
End of Cycle Audio = Low (5 seconds)
End of Cycle External Signal = Enabled (5 seconds)
Clean Lint Screen Reminder = Off
Display Limit Errors = Disabled
Manual Diagnostics = Enabled (accessable via PC and 
PDA only)
*Manual Programming = Enabled (accessable via PC 
and PDA only)
**Reverse Cylinder Rotate Time = 120 (seconds)
**Reverse Cylinder Stop Time = 6 (seconds) 
**Advanced Reversing = OFF
***Advanced Options for Moisture Dry = Disabled
***Display Moisture Sensor Error = Disabled
*If manual programming is disabled, programming 
changes to UniLinc can only be made with an external 
communication device. Refer to UniLinc PC and 
PDA Application User Instructions.
**Only available on units equipped with reversing 
feature.
***Only available on units equipped with moisture 
sensing feature.
Refer to Factory Defaults, Menu section for 
information on Restoring Factory Defaults.
Entering Program Mode
1. Press and hold
, then
, then
to 
enter the System Menu. Select Program to enter 
programming options.
PHM1003R
Figure 2 
PHM1004N
Figure 3 
Invalid Data