Alliance Laundry Systems 504523R3 User Manual

Page of 82
504523
9
Dryer Slide Extension . . .
1. Assemble coin slide extension, No. 503733, to top 
side of coin slide using two Phillips head screws and 
lockwashers, No. 03950.  Tighten firmly. 
2. Install slide extension modifier, No. 501796, as 
follows:
NOTE: Dryers equipped with Greenwald coin slides 
(except for Greenwald Comet Slide or Greenwald 
Tokette Slide) do not require the use of the slide 
extension modifier.
ESD Coin Slide – Mount slide extension 
modifier, No. 501796, to the underside of slide 
extension, No. 503733.  Align the hole in the slide 
extension modifier with hole “A” in the slide 
extension and install self-tapping screw, No. 
501086.  Tighten firmly.
GREENWALD Comet Slide, GREENWALD 
Tokette Slide or MONARCH Coin Slide
 – 
Mount slide extension modifier, No. 501796, to 
the underside of slide extension, No. 503733.  
Align the hole in the slide extension modifier with 
hole “B” in the slide extension and install self-
tapping screw, No. 501086.  Tighten firmly. 
3. Reinstall coin slide in dryer meter case.
4. CHECK DRYER OPERATION – Connect electrical 
power to dryer.  Place required number of coins in 
coin slide.  Push slide in, and observe through service 
door opening in meter case.  The slide extension 
should be contacting the accumulator actuator arm 
and moving back with slide travel.
When slide is pushed all the way in, slide is retracted.  
Accumulator actuator arm should remain back until 
slide extension is moved forward and contacts 
actuator arm agian, returning arm to starting position. 
5. After completing the dryer check, reinstall service 
door on top of meter case.
NOTE: When reinstalling service door, front of door 
must be inserted at about a 45
° angle in order to engage 
notched tabs with internal rib at top of meter case.
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be 
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
D019KE1C
COIN
SLIDE
03950
PHILLIPS
HEAD
SCREWS
AND
LOCKWASHERS
HOLE "B"
503733
SLIDE
EXTENSION
HOLE "A"
501796
SLIDE EXTENSION
MODIFIER
501086
SELF-TAPPING
SCREW
D044KE1A
ACCUMULATOR
ACTUATOR ARM
SLIDE
EXTENSION
MODIFIER
SLIDE
EXTENSION
COIN
SLIDE