Installation
13
513220
Figure 6 
Figure 7 
D686I
1
NOTE: Where the exhaust duct pierces a 
combustible wall or ceiling, the opening must be 
sized per local codes.
3
2 in. (5 cm) Minimum or Clearance per Local 
Codes
4
No Screen or Cap
2
Wall
5
Clean Out Cover 
 Inspect Monthly
D686I
2
3
4
EXHAUST 
OUTLET
K
J
I
H
G
F
E
D
C
B
A
5
30°
1
24 in. (61 cm)
MINIMUM 
CLEARANCE TO 
ROOF/GROUND
EXHAUST AIR FLOW MAXIMUM 
LENGTH OF DUCT 30 feet (9.1 m)
HORIZONTAL EXHAUST INSTALLATION
AIR 
FLOW
D753I
1
Roof
2
No Screen or Cap
3
Wall
4
2 in. (5 cm) Minimum
5
NOTE: Where the exhaust duct pierces a 
combustible wall or ceiling, an opening must 
be sized as shown or per local codes.
3
1
4
5
24 in. (61 cm)
MINIMUM 
CLEARANCE TO 
ROOF/GROUND
CONNECT TO DRYER
VERTICAL EXHAUST INSTALLATION
2
To reduce the risk of fire and the 
accumulation of combustion gases, DO NOT 
exhaust dryer air into a window well, gas 
vent, chimney or enclosed, unventilated 
area, such as an attic, wall, ceiling, crawl 
space under a building or concealed space 
of a building.
W045
WARNING