Installation
23
513220
The dryer is designed to be operated on a separate 
branch, polarized, three-wire, effectively grounded, 
120 Volt, 60 Hertz, AC (alternating current) circuit 
protected by a 15 Ampere fuse, equivalent fusetron or 
circuit breaker.
The three-prong grounding plug on the power cord 
should be plugged directly into a polarized three-slot 
effectively grounded receptacle rated 120 Volts AC 
(alternating current) 15 Amps. Refer to Figure 31 to 
determine correct polarity of the wall receptacle.
Grounding Information
The dryer must be grounded. In the event of 
malfunction or breakdown, grounding will reduce the 
risk of electric shock by providing a path of least 
resistance for electric current. The dryer is equipped 
with a cord having an equipment-grounding conductor 
and a three-prong grounding plug. The three-prong 
grounding plug on the power cord should be plugged 
directly into a polarized three-slot effectively 
grounded receptacle rated 110/120 Volts AC 
(alternating current) 15 Amps.
Do not modify the plug provided with the dryer – if it 
will not fit the outlet, have a proper outlet installed by 
a qualified electrician.
NOTE: Have a qualified electrician check the 
polarity of the wall receptacle. If a voltage reading 
is measured other than that illustrated, the 
qualified electrician should correct the problem.
Do not operate other appliances on the same circuit 
when this appliance is operating.
M
Step 8: Recheck Steps 1-7
Refer to Installer Checklist on the back cover of this 
manual and make sure that dryer is installed correctly.
Step 9: Check Heat Source
Electric Dryers
Close the loading door and start the dryer in a heat 
setting (refer to the Operation section). After the dryer 
has operated for three minutes, the exhaust air or 
exhaust pipe should be warm.
This dryer is equipped with a three-prong 
(grounding) plug for your protection 
against shock hazard and should be 
plugged directly into a properly grounded 
three-prong receptacle. Do not cut or 
remove the grounding prong from this plug.
W036
WARNING
Improper connection of the equipment-
grounding conductor can result in a risk of 
electric shock. Check with a qualified 
electrician or service person if you are in 
doubt as to whether the dryer is properly 
grounded.
W038
WARNING
DRY2022N
1
L1
2
Ground
3
Neutral
4
Neutral Side
5
Round Grounding Prong
Figure 31 
To reduce the risk of an electric shock or 
fire, DO NOT use an extension cord or an 
adapter to connect the dryer to the electrical 
power source.
W037
WARNING
D254I
DRY2
0 V.A.C
120±12
V.A.C
Plug cord into separately fused 15 Amp circuit.
3
2
1
4
5
120±12
V.A.C