Installation/Operation Supplement
70392201 (EN)
20
Electrical Requirements
Grounding Instructions
NOTE: To ensure protection against shock, this 
tumbler MUST be electrically grounded in 
accordance with the local codes or, in the absence of 
local codes, with the latest edition of the National 
Electrical Code ANSI/NFPA No. 70. 
In the event of malfunction or breakdown, grounding 
will reduce the risk of electric shock by providing a 
path of least resistance for electric current. This 
tumbler must be connected to a grounded metal, 
permanent wiring system; or an equipment grounding 
conductor must be run with the circuit conductors and 
connected to the appropriate ground location.
Metal conduit and/or BX cable is not considered 
ground.
Connecting the Neutral from the electrical 
service box to the tumbler ground screw does not 
constitute a ground.
A dedicated ground conduit (wire) must be 
connected between the electrical service box 
ground bar and the tumbler ground screw.
All manually operated models are factory-equipped 
with an emergency stop button on the front panel. 
NOTE: Activation of the emergency stop button 
stops all machine control circuit functions, but 
DOES NOT remove all electrical power from 
machine.
NOTE: This manual is only a supplement. Refer to 
installation/operation manual for full instructions.
WARNING
To reduce the risk of electric shock, fire, 
explosion, serious injury or death:
• Disconnect electric power to the tumbler 
before servicing.
• Close gas shut-off valve to gas tumbler 
before servicing.
• Close steam valve to steam tumbler 
before servicing.
• Never start the tumbler with any guards/
panels removed.
• Whenever ground wires are removed 
during servicing, these ground wires 
must be reconnected to ensure that the 
tumbler is properly grounded.
W002
To reduce the risk of fire and electric 
shock, check with a qualified serviceman 
for proper grounding procedures. Improper 
connection of the equipment grounding 
conductor may result in a risk of electric 
shock.
W068
To reduce the risk of fire and electric 
shock, if electrical supply is coming from a 
three phase service, DO NOT connect a 
“High Leg” or “Stinger Leg” to a single 
phase machine. On a three phase machine, 
if there is a “High Leg” or “Stinger Leg” it 
should be connected to L3.
W069
To reduce the risk of electrical shock, 
de-energize the electrical circuit being 
connected to the tumbler before making 
any electrical connections. All electrical 
connections should be made by a qualified 
electrician. Never attempt to connect a live 
circuit.
W409
WARNING
Label all wires prior to disconnection when 
servicing controls. Wiring errors can cause 
improper and dangerous operation. Verify 
proper operation after servicing.
W071