Gas Requirements
70304601
34
High Altitude Burner Orifice Sizing
For proper operation at altitudes above 2000 feet 
(610 meters), the gas burner orifice size must be 
reduced to ensure complete combustion. Refer to 
Table 7.
For CE models, consult local gas supplier.
Model
Gas
Altitude
Burner Orifice
New Rate
Feet
Meters
No.
Inches
mm
Quantity
Part 
Number
(Btu/hr.)*
T30
Natural Gas
2001-4000
610-1220
22
0.1570
4.0
2
M402996
134,320
4001-6000
1221-1830
24
0.1520
3.9
M402980
122,640
6001-8000
1831-2440
26
0.1470
3.7
M401000
110,960
8001-10,000
2441-3050
28
0.1405
3.6
M401014
99,280
L.P. Gas 
2001-6000
610-1830
42
0.0935
2.4
M403017
134,320
6001-8000
1831-2440
43
0.0890
2.3
M406184
110,960
8001-10,000
2441-3050
44
0.0860
2.2
M401011
99,280
T45
Natural Gas
2001 – 4000
610 – 1220
15
0.1800
4.6
2
M411511
183,000
4001 – 6000
1221 – 1830
17
0.1730
4.4
M411374
168,400
6001 – 8000
1831 – 2440
18
0.1695
4.3
M402988
155,000
8001 – 10000 2441 – 3050
20
0.1610
4.1
M401002
142,600
L.P. Gas 
2001 – 4000
610 – 1220
36
0.1065
2.7
M402487
183,000
4001 – 6000
1221 – 1830
37
0.1040
2.6
M411375
168,400
6001 – 8000
1831 – 2440
38
0.1015
2.6
M411376
155,000
8001 – 10000 2441 – 3050
40
0.0980
2.5
M406361
142,600
* Btu/hr. derate of 4% per 1000 feet (305 meters) of altitude.