Alliance Laundry Systems Drying Tumbler User Manual

Page of 22
Operating Instructions
70400101
12
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Run Mode
In Run Mode, the control is running a cycle. The IN 
USE
 LED is lit.
Door Open Mode
In Door Open Mode, the control turns off the heater 
and motor when the door is opened during a run 
cycle. The timer will continue to count down time 
and the IN USE LED is lit.
End of Cycle Mode
In End of Cycle Mode, a cycle is complete and the 
IN USE
 LED is off. The control remains in this 
modeuntil the door is opened or additional vend has 
been satisfied
Topoffs
Any time the control receives a coin drop pulse during 
a cycle it will add the programmed dry time to the time 
currently remaining in the cycle. The maximum cycle 
time is 99 minutes, the control will not add time 
beyond 99 minutes. The cool down time will not 
change. 
If the control receives a coin drop pulse during cool 
down the IN USE LED will flash briefly to indicate the 
coin input, the machine will exit cool down and it will 
start heating. The cycle time will be equal to the 
programmed dry time
Temperature Selector Switch
For five minutes after the control is powered up, there 
is a diagnostic feature that allows the temperature 
selector switches to be tested. 
When the temperature selector is changed, the new 
setting is displayed by flashing the IN USE LED as 
follows:
High/Normal: 4 flashes
Medium/PP: 3 flashes
Low/Delicate: 2 flashes
No Heat: 1 flash
NOTE: To change dipswitch settings refer to 
Installation Manual
.
Error Codes 
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be 
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
Display
Definition
Corrective Action
AF (flashing)
Airflow switch opened/closed 5 or 
more times in a running cycle.
Check airflow switch. Replace if inoperative.