Kenmore 110.9787 User Manual

Page of 52
10
Clamps
Use clamps to seal all joints. 
Exhaust vent must not be connected or secured with screws 
or other fastening devices that extend into the interior of the 
duct. Do not use duct tape.
Exhaust
Recommended hood styles are shown here.
The angled hood style (shown here) is acceptable.
An exhaust hood should cap the vent to keep rodents and 
insects from entering the home.
Exhaust hood must be at least 12" (30.5 cm) from the ground 
or any object that may be in the path of the exhaust (such as 
flowers, rocks or bushes, snow line, etc.).
Do not use an exhaust hood with a magnetic latch.
Plan Vent System
Choose your exhaust installation type
Recommended exhaust installations 
Typical installations vent the dryer from the rear of the dryer. 
Other installations are possible.
Optional exhaust installations
This dryer can be converted to exhaust out the right side, left 
side, or through the bottom.
 
Contact your local dealer to have the 
dryer converted.
Clamp
A. Louvered hood style
B. Box hood style
     4"
(10.2 cm)
      4"
(10.2 cm)
B
A
   4"
(10.2 cm)
2½"
(6.4 cm)
Improper venting can cause moisture and lint to collect 
indoors, which may result in:
Moisture damage to woodwork, furniture, paint, wallpaper, 
carpets, etc.
Housecleaning problems and health problems.
A. Dryer
B. Elbow
C. Wall
D. Exhaust hood
E. Clamps
F. Rigid metal or flexible metal vent
G. Vent length necessary to connect elbows
H. Exhaust outlet
A. Standard rear offset exhaust installation
B. Left or right side exhaust installation
C. Bottom exhaust installation (not an option 
with pedestal installations)
H
G
F
E
D
C
A
B
WARNING
Fire Hazard
Cover unused exhaust holes with one of the 
following kits:
279818 (white)
279915 (black diamond)
280102 (pacific blue) 
280103 (champagne) 
280189 (barolo)
Contact your local dealer.
Failure to follow these instructions can result in death, 
fire, electrical shock, or serious injury.