Fujifilm FinePix S5 Pro User Manual

Page of 244
68
Metering
Normally, the matrix metering system will provide the 
optimum exposure for your shot. However, you can 
choose from 3 metering modes for shots where you want 
to select a different exposure level (AE lock or exposure 
compensation) or for particular scenes (such as backlit 
shots or shots with very strong contrast).
Turn the metering selector to desired metering system.
1,005-pixel RGB sensor sets exposure based on variety 
of information from all areas of frame. With type G or D 
lens, camera uses 3D color matrix metering II for natural 
results even when frame is dominated by bright (white or 
yellow) or dark (black or dark green) colors. 
With other CPU lenses, 3D range information is not 
included; instead, camera uses color matrix metering II. 
Color matrix metering is available when a non-CPU lens 
is attached and if the focal length and maximum aperture 
of the lens are specified for [NON-CPU LENS DATA] 
under [
MISC.] in the [SET UP] menu (
➝p.121; the 
center-weighted metering is used if focal length or 
aperture is not specified). 
• For AE lock (
➝p.69) or Exposure compensation 
(
➝p.76), the Spot metering is recommended.
Camera meters entire frame but assigns greatest weight 
to area in center of frame 8 mm (0.31 in.) in diameter, 
shown by corresponding 8-mm reference circle in 
viewfinder. 
MEMO
The metering diameter can be changed by the [CENTER-
WEIGHT AREA] setting under [SEXPOSURE] in the 
[SET UP] menu. Also, the average metering value of the 
entire frame is available (
p.157).
Camera meters circle 3 mm (0.12 in.) in diameter 
(approximately 2.0% of frame). Ensures that subject will 
be correctly exposed, even when back ground is much 
brighter or darker.
• Circle is centered on current focus area (in group 
dynamic AF, on center focus area of current group; 
➝p.56), making it possible to meter off-center subjects 
(if non-CPU lens is used or if dynamic-area AF with 
closest subject priority is in effect, camera will meter 
center focus area). 
MEMO
• For improved precision with non-CPU lenses, specify 
lens focal length and maximum aperture in [NON-CPU 
LENS DATA] under [
MISC.] in the [SET UP] menu.
• When using non-CPU lens, center-weighted metering is 
used if focal length or aperture is not specified in [NON-
CPU LENS DATA] under [
MISC.] in the [SET UP] 
menu.
• Center-weighted is recommended when using filters 
with an exposure factor (filter factor) over 1x.
 Matrix metering
 Center-weighted
 Spot