Toshiba CS3950D User Manual

Page of 23
 
 
 
   
10 
D4133738B
 
[Mechanical spec] 
(1) External dimension 
44 x 29 x 78(D) mm (Not including protrusion) 
Refer to the attached external view drawing 
(2) Weight 
 Approximately 130g 
(3) Lens mount   
 C mount 
(4) GND / insulation 
 Circuit GND - Chassis electrically conducted 
 
* Combination of C
Combination of C
Combination of C
Combination of C----mount lens
mount lens
mount lens
mount lens    
As  for  the  C-mount lens  used combining  this camera, the  projection distance from 
bottom of the screw should use 8.3mm or less. 
 
 
 
 
 
 
 
 
[Ambient condition] 
(1)Environment condition 
Performance guaranteed  Temperature: From 0 through 40 °C 
Humidity: From 30 through 90 % (No condensing) 
Operation guaranteed 
Temperature: From -5 through 50 °C 
Humidity: From 10 through 90 % (No condensing) 
Storage 
Temperature: From -20 through 60 °C 
Humidity: From 10 through 90 % (No condensing) 
(2)EMC conditions (Electro-Magnetic Compatibility) 
EMI (Electro-Magnetic Interference) 
EN61000-6-4 (Examination level EN55011-A) Conformity 
EMS (Electro-Magnetic Susceptibility) 
EN61000-6-2 Conformity 
*Conformity of EMC conditions 
About  the  conformity  of  the  EMC  standard  of  this  machines,  it  has  guaranteed  in  the 
conditions combined with the option part of 4th clause. 
When  used  combining  parts  other  than  specification  of  our  company,  I  ask  you  to  have 
final EMC conformity checked of a visitor with a machine and the whole equipment. 
 
 
 
 
 
 
 
 
8.3mm or less
C-mount lens
Bottom of
the screw