CBC ZC-PT226 User Manual

Page of 52
 
   
                             
User’s Manual 
 
 
10
be the same. The default RS-485 setting is half-duplex. Please do not change the 
default setting without seeking the advice of a qualified specialist or the supplier. Pin 3 
and pin 4 are used for termination and line lock adjustment respectively. Pin 5 is 
mainly used after updating the software and changing protocol. 
 
RS-485 setting 
Half-duplex 
 
Full-duplex 
 
 
 
2.4 
PTZ Camera ID Setting 
Use the switch to change your PTZ camera ID by turning the arrow to the desired 
number. For example, if the camera ID is 123, the ID switch should be set as below. 
 
 
NOTE:
 No two cameras should be given the same ID or communication 
conflict may occur.
 
 
 
Hundreds                 Tens       
        Units
 
 
NOTE:
 The number “0” should be located at the top as shown in above 
diagram to ensure correct switch definition.
 
 
 
2.5 
PTZ Camera Control Protocol 
A protocol is a specific set of rules and procedures used for data communication. 
Define the protocol you are going to use based on the devices in your surveillance 
system. Generally, you should use a single protocol even if the devices are supplied 
by different manufacturers. Use the switch to set your PTZ camera control protocol 
and the baud rate. Refer to the table below and turn the arrow to choose a protocol for 
your camera.