Emerson Process Management 3-9000-760 Revision E User Manual

Page of 128
Daniel 3814 Liquid Ultrasonic Meter Installation Manual
Section 3: Electrical installation
3-9000-760 Rev E
March 2015
Frequency/Digital outputs
 53
  
Output for FODO1 and Digital Output1 (Group 1 on the CPU Module) share a common ground 
and have 50V isolation. FODO2 and FODO3 (Group 2 on the CPU Module) share a common 
ground and  have 50V isolation. This allows an output  to be connected to a different flow 
computer. The outputs are opto-osculated from the CPU Module and have a withstand voltage 
of at least 500V rms dielectric.   
Figure 3-6  CPU Module - Frequency/Digital outputs common ground 
Table 3-5  Frequency/Digital Outputs possible configurations
Frequency/Digital output 
Source configuration
Frequency /Digital Output 1
1
Frequency /Digital Output 2
2
or 
Frequency /Digital Output 3
1.  
Solid blue line denotes valid selection for Frequency/Digital Output 1.
 
2.  Black dashed -line denotes valid selections for Frequency/Digital Output 2 and Frequency/Digital 
Output 3. 
Frequency output 1A
Frequency output 1B
Digital output 1A
Digital output 1B
Frequency output 1A
Frequency output 1B
Digital output 1A
Digital output 1B
Frequency output 2A
Frequency output 2B
Digital output 2A
Digital output 2B
FODO1
FODO2
FODO3
FO1A
FO1B
DO1A
DO2B
FO2A
FO2B
DO2A
DO2B
A.
A. FODO1 and Digital input1 - shared common ground (Group 1)
B. FODO2 and FODO3 - shared common ground (Group 2)
B.