Zebra Technologies TTP 2100 User Manual

Page of 36
17
Installation
Top of Form (TOF) Sensor
11/04/2009
TTP 2100 Operator Guide
P1021708-001
Calibrating the TOF Sensor
1.
Open the printhead.
2.
Remove ticket stock.
3.
Press and hold the Feed button, and then close the printhead (keeping the button pressed 
all the time).
4.
Release the button. 
The Status LED should be off. 
5.
Load ticket stock (slide it into the paper guide and let the printer auto load the paper).
The printer will forward the paper until it finds two TOF marks and then stop and save all 
TOF-mark parameters.
7.
Close the printhead and feed the tickets in through the paper guide again.
The printer is ready for use.
Repeat this procedure if the calibration fails or if the printer is used with tickets that differ 
from the original specification.
Note • 
If you use the Dual guide 01990-400 on your printer, you must calibrate twice (once 
in the wide paper path and once in the narrow). The printer will choose the appropriate set of 
parameters based on which paper path contains ticket stock.