System Configuration
 
 
Attach the Camera adapter(CA-HF1500) to the Camera head(SK-HD1500). Then connect the camera 
control panel and setup control unit to the CU-HD1500. 
 
1. AC power supply operation 
When  the  CU-HD1500  CCU  POWER  switch  is  set  to  ON,  the  optical  fiber  cable  connection  is 
checked automatically (it takes about 5 seconds), and then power can be supplied to the camera by 
pressing the CAMERA POWER button to enable a video output signal. 
The CABLE CHECK LED lights OK when the optical fiber cable is normal. 
The intercom system is available when the CCU POWER switch is ON. 
 
Note:
 When operation mode is changed from MAIN mode to STBY mode, wait for 10 seconds to 
restart the camera power. 
   
 
Camera Head
SK-HD1500
Optical Fiber Cable
Camera control unit
CU-HD1500
Remote Control Unit
RU- 1500
Camera Adaptor
AC input
CA-HF1500
 
 
2. Camera stand alone operation 
Supply 12VDC to  the CA-HF1500, but  do  not  connect  either  optical  fiber  cable  or  SM  fiber  cable. 
The camera can be operated in stand-alone mode. The video signal appears at the camera MONI 
OUT and SDI OUT1/2 connectors.