Hitachi JU-1000 User Manual
- 26 -
Gateway PC program install & setup
1.) Installation
Copy the HITACHI
“CTVIPcontrolSystem” Folder onto an arbitrary drive/folder.
The main application is registered to the STARTUP menu group after installation.
2.) File Configuration
IPCSYS.exe
Main Application
CTVIPControlSystem.ini
Initialization File
CTVIPControlSystem.dat
Internal Data (Please do not delete it)
LOG Folder
Communication Log
3.) Initialization File
[Socket]
connect_wait_time = 100
connect_wait_time = 100
socket connection timeout [msec]
recv_retry_timeout = 10
received retry interval [msec]
recv_wait_time = 10
received wait timeout [msec]
[Serial]
recv_retry_timeout = 10
recv_retry_timeout = 10
received retry timeout [msec]
4.) Log File
File name
=
IPCONTROL_1_20091003.log
IPCONTROL_
=
fixed
1_
=
RU’s number (1 ~ 8)
Configuration
2001, 2009-10-
2001, 2009-10-
0317:37:19.761168,[CNTL ←CUCU], message box
1 2 3 4
1 Starting from number 1000, 1001 ~ 1008 indicate the transmission with RU.
Starting from number 2000, 2001 ~ 2008 indicate the transmission with CCU.
2 Record date
the decimal point is μSec.
3 Transmission Direction
CNTL expresses the main system.
CUCU stand for CCU,
RURU stand for RU
CNTL → RURU transmitting from PC to RU
CNTL ← RURU receiving from PC to RU
CNTL → CUCU transmitting from PC to CCU
CNTL ← CUCU receiving from PC to CCU
4 Message box
Transmission data display HEX and ASCII array, string length.
The others display message.
(Example)
Socket Connect Success [192.168.0.2:10001] = Connect Success
Serial Connect Success [9600, n, 8, 1] = Connect Success
Serial Disconnect Success = Disconnect Success
Socket Connect Success [192.168.0.2:10001] = Connect Success
Serial Connect Success [9600, n, 8, 1] = Connect Success
Serial Disconnect Success = Disconnect Success