Fujitsu MCE3064SS User Manual

Page of 181
C156-E097-01EN
2 - 5
2.1.3
Environmental and power requirements
Table 2.3 lists the environmental and power requirements.
Table 2.3
Environmental and power requirements (1 of 2)
Item
Specification
Power
requirements
Average
+5 VDC±5%,  1.1 A (2.5 A Max., excluded for
terminating resistor) (*1)
Ready
3.9 W (*2)
Random seek, read, or write
(*2)
4.9 W (TYP) (*2)
Power save
0.5 W (MIN) (*2)
With panel
101.6
×
150.0
×
25.4 mm
Without panel
101.6
×
148.4
×
25.4 mm
Weight
470 g (with panel)
Environmental
requirements
Operating
Temperature:            5 to 45 °C (*3)
                                (gradient 15 °C /h or less)
Relative humidity:  10 to 85% (Noncondensing)
Max. wet bulb temperature:    29 °C or lower
Idle
Temperature:            0 to 50 °C
Relative humidity:  10 to 85 % (Noncondensing)
Max. wet bulb temperature:    36 °C or lower
Transport
Temperature:     –40 to 60°C (24 hours or less)
Temperature:     –20 to 60°C (24 hours or more)
Relative humidity:  5 to 90% (Noncondensing)
Max. wet bulb temperature:    41 °C or lower
Requirement:  Packing conditions specified by Fujitsu
Installation
Tilt angle
–5° to +10°
Vibration/
shock
Operating
            0.4 G (5 to 500 Hz, sine sweep)
Shock  2 G (10ms, half-sine pulse)
Idle
No cartridge, power ON
            1.0 G (5 to 500 Hz, sine sweep)
Shock  5 G (10 ms, half-sine pulse)
Transport
Shock  50 G (10 ms, half-sine pulse)
Requirement:  Packing conditions specified by Fujitsu
Altitude
Operating
3,000 m (10,000 ft) or less
Idle
12,000 m (40,000 ft) or less
Power
consumption
Dimensions
(W
×
D
×
H)