Honeywell 2-Partitioned Security System User Manual

Page of 36
 
– 25 – 
PROMPT 
EXPLANATION 
 
 
01  ADD ZONE # 
00=QUIT 00 
Using 2-digit entries, enter each zone to be included in this zone list. Press [
✱] after you enter each zone 
number. 
When you have entered all zones, enter 00
Press [
✱] to continue. 
 
01  Del  Zn  LIST  ? 
  1=YES    0=NO 
Enter 0 to save this zone list. Enter 1 to delete it.  
 
01     DEL  ZONES ? 
  1=YES    0=NO 
Enter 1 to delete one or more zones in that zone list.  Enter 0 if no changes are necessary.  If you enter 1, 
the following screen appears; otherwise, the "Enter Zone LIST" prompt reappears.  
 
01  Zn  to  DELETE ? 
00=QUIT 00 
Enter each zone number to be deleted from the zone list, pressing [
✱] after each number. 
 
VIEW  Zn  LIST  ? 
00=QUIT 00 
This display appears if you pressed 00 at the “Enter Zone LIST” prompt.  Enter the zone list number that you 
wish to view.  
Press [
✱] to continue.  
 
01  ASSIGNED ZONE 
00=QUIT 00 
Press [
✱] to scroll through all zones in that list. Enter 00 +[✱] to quit. 
Press 1 to exit Menu Mode. 
Press [
✱]99 to exit Program Mode. 
Relay Voice Descriptors 
If you are using the 4285/4286 VIP Module, you can program voice descriptors for each relay output.  The descriptors are 
announced by the voice module when you access the relays via the # 70 Relay Access Mode over the telephone.  
Each voice descriptor can consist of up to 3 words selected from the Relay Voice Descriptors and Custom Word Substitutes 
Vocabulary list (later in this section). 
 
 
The index numbers from this vocabulary list are to be used for relay voice descriptors only. For normal 
system voice annunciation (e.g., alarms, troubles, status), use the highlighted words in the alpha vocabulary 
list in the Alpha Programming part of this guide. 
 
To enter relay voice descriptors, do the following: 
1.  From Data Field Programming mode, press #93 to display the "ZONE PROG?" prompt.  
2. Press 
0 (NO) to each menu option until the "RLY VOICE DESCR?" prompt is displayed.  Follow the instructions below.  
While in this mode, press [
✱] to advance to next screen. Press [#] to back up to previous screen. 
PROMPT 
EXPLANATION 
 
 
RLY VOICE DESCR? 
1=YES    0=NO 
Press 1 to program voice descriptors for relays. 
 
ENTER RELAY NO. 
00=QUIT            01 
Enter the 2-digit relay number (01-08) for the relay desired, or enter 00 to quit Relay Voice Descriptor 
Programming Mode. 
Press [
✱] 
 
01 ENTER DESC  d1 
 
From the Relay Voice Descriptors and Custom Word Substitutes Vocabulary list, enter the 3-digit index 
number for the first word of the relay descriptor phrase.  
Press [
✱] to accept entry. 
 
01 ENTER DESC  d2 
 
From the Relay Voice Descriptors and Custom Word Substitutes Vocabulary list, enter the 3-digit index 
number for the second word of the relay descriptor phrase. If second word is not desired, press 000.  
Press [
✱] to accept entry. 
 
01 ENTER DESC  d3 
 
From the Relay Voice Descriptors and Custom Word Substitutes Vocabulary list, enter the 3-digit index 
number for the third word of the relay descriptor phrase. If third word is not desired, press 000.   
Press [
✱] to accept entry.  The “ENTER RELAY NO.” prompt appears.  Enter the next relay number to be 
programmed.  When you have programmed all relay devices, enter 00 to quit. 
Enter [
✱]99 to exit Program Mode.