The OmniLT has 2 (expandable to 10) outputs that can be used to switch relays.   Outputs 1 and 2 are controlled by unit numbers 
27 and 28.  These are hardwired outputs that are connected directly through the OmniLT and not through a module.  If you have 
something connected to these outputs, such as a sprinkler system, your dealer will explain its operation. 
 
• 
Outputs cannot be brightened or dimmed. 
• 
Outputs are not affected by All ON or All Off commands. 
 
 
All On / Off 
 
The All On/Off menu is used to turn all lighting unit numbers on and off.   
 
Note: UPB, CentraLite, and RadioRA devices are not affected by the OmniLT “All On” or “All Off” command.   To achieve this 
functionality, we suggest the following: 
 
UPB: Program a Link into each device that will respond to an OmniLT “All On” and “All Off” command program.  For example: 
 
In each UPB switch that will respond to “All Off” and “All On”, program a Link (in this example, Link 50 is used) that 
will go to 100% when activated (turned on).  Then write the following programs in the OmniLT controller: 
 
WHEN ALL ON: LINK 50 ON 
 
 
 
WHEN ALL OFF: LINK 50 OFF 
 
CentraLite:  Program the “All On” and “All Off” macro to execute an All On Scene and an All Off Scene on the 
CentraLite. 
 
RadioRA: Program the “All On” and “All Off” macro to execute Phantom Button 16 (All On) and Phantom button 17 (All Off).   
 
For example: 
 
WHEN ALL ON: PHANTOM BUTTON 16 ON 
WHEN ALL OFF: PHANTOM BUTTON 17 ON
 
 
This All On/Off menu is also used to control Leviton Scenes, RadioRA Phantom Buttons, UPB Links, and CentraLite Scenes. 
 
From the top-level display or from the main menu, press the 4 (ALL) key on the console keypad. 
 
 
 
 
ALL
 
   0=OFF 
1=ON 
2=SCN 
3=LINK
↓ 
 
 
 
 
ALL
 
 
 
 
4=PHANTOM 5=CENLIT     
↓ 
 
 
All Lights On 
 
At the ALL prompt, press the 1 (LIGHTS ON) key.  The console will beep, and a command will be sent that turns on all specified  
X-10 or ALC units or HLC Rooms.  X-10 Appliance Modules do not respond when the All Lights On command is sent.  By 
factory default, all lighting units respond to the All-On command. 
 
NOTE:  The All On function can be changed, if desired - See Set Up Misc, All On And All Off
 
All Off 
 
At the ALL prompt, press the 0 (OFF) key.  The console will beep, and a command will be sent that turns off all specified X-10 
and ALC units and HLC Rooms.  By factory default, all lighting units respond to the All-Off command. 
 
NOTE:  The All Off function can be changed, if desired - See Set Up Misc, All On And All Off
23