Home Automation SECURITY SYSTEM User Manual

Page of 82
 
FORMAT NUMBER 
DESCRIPTION 
 
STANDARD 
 
 
 
Preset Dim Command (X-10, X-10 Pro, Leviton, PCS, etc.) 
EXTENDED 
 
 
 
Extended Code Level Command (Leviton) 
COMPOSE 
   2 
Compose 
Mode 
(Lightolier's 
Compose) 
UPB 
    3 
Universal 
Powerline 
Bus 
(open 
format) 
RADIO 
RA 
   4 
Lutron 
RadioRA 
HAI 
LIGHTING 
   5 
HAI 
Lighting 
Control 
(HLC) 
CENTRALITE 
   6 
CentraLite 
Lighting 
 
The default setting for HC 1 Format is 5 (HLC). 
 
 
House Code All Off 
 
This feature allows you to choose if the House Code will respond to the “All Off” command.  Press the 0 key to select No and the 
1 key to select Yes.   
 
 
 
HC 1 ALL OFF:           1
 
 
 
0=NO 1=YES              
 
 
The default setting for HC 1 All Off is Yes. 
 
Notes:
  
 
1.  When configured, the House Code will affect 2 rooms of HLC lighting (i.e. HC 1 ALL OFF affects Room 1 and 2). 
 
2.  When the House Code is configured as UPB, RadioRA, or CentraLite, “House Code All Off” does not affect the state of the 
installed devices; however, if this setup item is set to “Yes”, OmniLT will change the status of all units on that House Code 
to “Off” (even though it doesn’t explicitly send an All Off command to those units).  If the “House Code All Off” setup item 
is set to “No”, OmniLT will not change the status of units on that House Code.   
 
House Codes  All On 
 
This feature allows you to choose if the House Code will respond to the “All On” command.  Press the 0 key to select No and the 
1 key to select Yes.   
 
 
 
HC 1 ALL ON:            1
 
 
 
0=NO 1=YES              
 
 
The default setting for HC 1 All On is Yes. 
 
Notes:
  
 
1.  When configured, the House Code will affect 2 rooms of HLC lighting (i.e. HC 1 ALL ON affects Room 1 and 2). 
 
2.  When the House Code is configured as UPB, RadioRA, or CentraLite, “House Code All On” does not affect the state of the 
installed devices; however, if this setup item is set to “Yes”, OmniLT will change the status of all units on that House Code 
to “On” (even though it doesn’t explicitly send an All On command to those units).  If the “House Code All On” setup item is 
set to “No”, OmniLT will not change the status of units on that House Code. 
 
Time Clocks 
 
There are three time clocks in the system are used to conditionalize programs.  They are used solely to define time periods during 
the week when certain programs should be enabled or disabled to execute.   
 
TIME CLOCK 1 ON 
TIME CLOCK 1 OFF 
 
Specify the On and Off times for each Time Clock - See Set Up Codes. 
 
 
 
 
TIME CLOCK 1 ON TIME:
 
64