OPTION PROGRAMMING 
 
 
NOTE:  Options can be instantly restored to Factory Default Values. 
 
To restore default values:  
 
Perform step #1 (See page 10), then press button 3 (trunk).  The siren and horn will chirp 4 times and 
lights will flash 4 times.  Turn OFF Ignition.  All programming options will be restored to * Default * values 
(See page 10). 
 
1. HORN CHIRPS / PULSES 
This  option  controls  the  system’s  Factory  Vehicle  Horn  output.    There  are  3  selections:  Button  1  (Lock)  =  Horn 
Pulse  only  when  alarm  is  tripped.    Button  2  (Unlock)  =  Horn  Chirps  for  Arm  /  Disarm  and  Pulse  when  tripped.  
Button  3  (Trunk)  =  Horn  Chirps  for  Arm,  Disarm,  and  Pre-warning  protection.    All  settings  provide  horn  pulses 
when triggered. 
 
2. PASSIVE ARMING / CHIRP COUNTDOWN 
This  option  controls  the  Passive  (Automatic)  Arming  feature.    If  ON,  arming  will  occur  30  Seconds  after  the 
ignition is turned off and the last door has been closed.  The LED will begin flashing rapidly while counting down.  
If a door is reopened, the system will  wait (LED OFF) for the door or  zone to close before arming.  The unit  will 
chirp once and flash the lights once. Doors will lock if passive locking is selected.  Factory default setting is OFF.  
If Passive Chirp countdown is selected, the System will produce a siren chirp every 2 seconds during countdown 
until the system arms. 
 
3. PASSIVE LOCKS / CUSTOM OVERRRIDE  
PASSIVE  LOCKS:    This  option  controls  whether  the  doors  will  lock  when  Passive  Arming  occurs.    Note:  May 
increase the risk of locking keys in the vehicle. When selected ON the alarm will  passively lock the  doors  when 
passive arming. 
 
4. IGNITION-CONTROLLED LOCKS 
This  option  controls  whether  the  locks  are  controlled  by  Ignition.    There  are  3  selections:  Button  1  (Lock)  = 
Lock/Unlock  with  vehicle  Ignition.    Button  2  (Unlock)  =  No  ignition  locks.    Button  3  (Trunk)  =  Ignition  lock  only.  
Doors will not lock if they are open to prevent locking the keys in
. 
 
5. DOOR OPEN WARNING (5 or 60 Seconds) 
This setting changes the delay time in which the alarm system begins to monitor the Door circuit.  This option can 
prevent the alarm from giving warning chirps on vehicles with a delayed dome light.