Desa HD-9240 User Manual

Page of 42
-10-
595-5631-07
Adjustments Continued . . .
Aim Sensor Down
for Short Coverage
Loosen the wing screws, estimate the direction to aim the sensor and
tighten the wing screws just enough to hold the sensor in place.
Walk through the coverage area noting where you are when the lights
turn on. Loosen the wing screws and readjust the sensor as necessary.
Tighten the wing screws (finger tight) when you are satisfied with the
coverage direction. Keep the sensor at least 1 inch (25 mm) from
lamps and keep the controls on the bottom.
Adjust SENSITIVITY as needed to increase or decrease the range. Too
much sensitivity may increase false triggering.
Set the amount of TIME (1, 5 or 20 minutes) you want the lights to stay
on after motion is detected at night .
If you need to detect objects more than 70 feet (21 m) away, turn Range
Boost on.
Replace the rubber cover to protect controls.
Aim Sensor Out for
Long Coverage
Expected Coverage
The sensor is less sensitive to motion directly
towards it, most sensitive to motion across its field
of view.
Sensor
Least Sensitive
Most Sensitive
Maximum Range
When mounted 8 feet (2.4 m) from the ground,
you may expect the range shown below. If
mounted much higher the sensor may miss ob-
jects near the ground. If mounted much lower the
sensor range may be reduced.
  8 ft.
(2.4 m)
Motion
Motion
70 ft.
100 ft.
(21 m)
(30,5 m)
(Boosted)