1.5 Installation Steps Summary 
 
Carefully and completely read the manuals for each piece of equipment 
before attempting to install and connect this equipment. 
Before you start connecting other optional accessory equipment to your 
system, make sure that all, power, video, VCR, and monitor connections are 
completed, and everything is working correctly.   
Wire the telemetry equipment according to that unit’s installation instruction.  
Use the internal diagnostic testing capabilities of the telemetry receiver to 
verify that the power and connections to the lens and motors are correct, and 
function properly. 
Using the Diagram on the following page, connect the equipment in the 
following order: 
1.  Connect the CBR-PB2-PHILIPS to the Kalatel unit (DVMRe 
Simplex, DVMRe Triplex, DVMRe Matrix) via RS-485 port using the 
RJ45 to RJ45 cable.  The maximum total distance allowed on the 
RS-485 data line (without signal amplification or modems) is 3,000 
feet (1,000 meters).  A 100-ohm terminator is required at each end 
of the RS-485 line. 
2.  Connect the CBR-KB3 or KTD-405 keypad to the Kalatel unit 
(DVMRe Simplex, DVMRe Triplex, DVMRe Matrix) via RS-485 port 
using the RJ45 to RJ45 cable. 
3.  Supply power to the Kalatel unit first and the CBR-PB2-PHILIPS 
second using the supplied AC to 12 VDC adapter. Via the Setup 
Menus for the Kalatel unit set the RS-485 network address to the 
appropriate number (see the Appendix for RS-485 addressing).   
4.  Using the provided cable, connect from the ProBridge RCVR/DRVR 
port to the Philips Data Converter Unit (LTC 8780).  See the Philips 
Data Converter Unit’s (LTC 8780) installation manual for 
information on connecting the LTC 8780 to the AutoDome. 
5.  Set the ID addresses for the Philips Dome according to the table 
later in this manual. 
6.  Via a networked connected PC with WaveReader software, 
connect to the DVMRe unit and confirm proper control and 
operation of the PTZ unit.   
 
Please note, that whenever the ProBridge is used with a KTD-405 
the KB3 PTZ Protocol option in the KTD-405 menu must be set to 
YES. See Supervisor Programming in the KTD-405 manual. 
 