Heath Zenith SH-5411 User Manual

Page of 16
© 2008 HeathCo LLC 
598-1157-05
Requirements
•  The light control requires 120-volts AC.
•  If you want to use Manual Mode, the control must be 
wired through a switch.
• 
Some  codes  require  installation  by  a  
qualified electrician.
•  This product is intended for use with the enclosed 
gasket and with a junction box marked for use in wet 
locations.
•  The backplate has knockouts so the sensor can be 
mounted on most junction boxes.
•  In some applications a universal adaptor plate may 
be needed. Adaptors are available at home centers 
and electrical supply stores.
Light Control
Sensor
Cover 
Plate
Lamp Holders
Features
•  Turns on lighting when motion is detected.
•  Automatically turns lighting off.
•  Photocell keeps the lighting off during daylight hours.
•  LED indicates motion was sensed (day or night).
Gasket
2 Wire
Connectors
This package includes:
4 Screws
(2 sizes included)
OPERATION
* resets to Auto Mode at dawn.
TEST
10 5 1 
TEST
ON-TIME
Put  the  ON-TIME  switch  on  the 
bottom of the sensor in the TEST 
position.
MANUAL MODE
ON-TIME
10 5 1 TEST
... back on.
AUTO
1 Second OFF 
then...
Note: When first turned on wait about 1 
1
/
2
 minutes for 
the circuitry to calibrate.
Manual  mode  only  works  at  night 
because  daylight  returns  the  sensor 
to AUTO.
Flip the light switch off for one second 
then back on to toggle between AUTO 
and MANUAL MODE.
Manual  mode  works  only  with  the 
ON-TIME  switch  in  the  1,  5,  or  10 
position.
Put the ON-TIME switch in the 1, 5, 
or 10 minute position.
Mode:
On-Time:
Works:
Day
Night
Test
5 Sec
x
x
Normal
1, 5, 10 min.
x
Manual
Until Dawn*
x
Model SH-5411
Motion Sensor
Light Control
Meets the ENERGY STAR
®
 guidelines 
when used with 120 W Max bulbs.