598-1167-05
Set  the  ON-TIME  switch 
on the bottom of the cover 
plate to 
TEST.
MANUAL MODE
... back on.
1 Second 
OFF then...
OPERATION
* resets to Auto Mode at dawn.
TEST
TEST 1 5 10 MIN
AUTO
TEST 
1 5 10 MIN
Set ON-TIME switch to 
1, 5, or 10 minutes.
Manual mode only works at 
night  because  daylight  re-
turns the sensor to AUTO.
Flip  the  light  switch  off  for 
one second then back on to 
toggle  between  AUTO  and 
MANUAL MODE.
Manual mode works only with 
the ON-TIME switch in the 1, 
5, or 10 position.
Mode:
On-Time
Works: Day Night
Test
5 Seconds
x
x
Auto
1, 5, or 10 Min
x
Manual
To Dawn*
x
Accent 3, 6 Hr, to Dawn
x
Note:  When first turned on wait about 1 
1
/
2
 
minutes for the circuitry to calibrate.
Before installation, record the model number 
from back of fixture below. Attach receipt in 
case of possible warranty issues.
Items
Models
066799
PF-4192-BK
067208
PF-4192-WH
253370
PF-4197-WH
Questions or problems? Before returning 
to your retailer, refer to the troubleshooting 
guide in this manual or call our technical ser-
vice department at 1-800-858-8501 (English 
speaking  only),  7:30  am  to  4:30  pm,  CST, 
Monday – Friday.
Features
•  Light comes on when motion is detected.
•  Automatically turns light off.
•  Dusk Accent lighting.
•  Photocell keeps the light off during daylight 
hours.
Package Contents
•  Lantern
•  Easy  to  use  Universal  Mounting  Bracket 
(X-bar)
•  Mounting Hardware
•  Wire Connectors
Requirements
•  The light control requires 120 volts AC.
•  If you want to use Manual Mode, the control 
must be wired through a switch.
• 
Some electrical codes require installa-
tion by a qualified electrician.
ON-TIME
ON-TIME
Meets  the  ENERGY  STAR
®
 
guidelines  when  D
ual
B
rite
®
 
function is off.