SECO-LARM USA SA-025EQ User Manual

Page of 12
ENFORCER Delayed Egress Timer 
 
2
 
                                                        SECO-LARM U.S.A., Inc.
 
 
 
Remote Alarm Relay Output ......................... 
     
Lock Relay Output ........................................ 8 
Local Alarm Output ....................................... 8 
Pre-Delay Bypass Input ................................ 8 
Free Egress Input ......................................... 9 
Reset Input .................................................... 9 
Initiate Input .................................................. 9 
Bypass Input ................................................. 9 
Lock Status Input .......................................... 9 
Power Input ................................................... 9 
Sample Applications .............................. 10-11 
Troubleshooting .......................................... 12 
Warranty ..................................................... 12 
 
3 Relock modes to meet different installation requirements: 
 
Standard manual relocking. 
 
BOCA (Building Officials Code Administrators) relocking. 
 
Timed relocking (1~60 seconds). 
 
Programmable nuisance delay timer (0~3 seconds). 
 
Adjustable pre-delay timer (1~30 seconds). 
 
Adjustable post-delay timer (1~60 seconds). 
 
Selectable manual or automatic relocking after power loss. 
 
Lock relay output (Form C, 10A@24VDC). 
 
Remote alarm relay output (Form C, 10A@24VDC). 
 
Local alarm output (transistor ground, 500mA@12VDC). 
 
Door status input. 
 
Status LEDs show relay status. 
 
Bypass input immediately releases locks. 
 
Free egress input allows easy egress during the day. 
Features: 
Specifications: 
Table of Contents: 
Operating voltage 
12~24 VAC/VDC 
Current draw 
Standby
1
 
120mA@12VDC 
Pre-delay 
90mA@12VDC 
Local alarm 
35mA@12VDC 
Timer module only
15mA@12VDC 
Lock control output  
10A@24VDC, Form C, NO/NC/COM 
Remote alarm output 
10A@24VDC, Form C, NO/NC/COM 
Local alarm output 
Transistor ground, 500mA@12VDC  
 
Features ........................................................ 2 
Specifications ................................................ 2 
Dimensions.................................................... 3 
Overview ....................................................... 3 
Installation ..................................................... 4 
Wiring Diagram.............................................. 4 
Relock Modes................................................ 5 
Adjusting the Pre-Delay and Post-Delay ....... 6 
Setting the Power-Up Mode and 
 
 
Nuisance Delay ............................................. 6 
Lock Status Jumper....................................... 7  
Security Mode Jumper .................................. 7 
Local Alarm Output Type Jumper.................. 7 
 
1
Lock relay and remote alarm relay are normally energized.  
2
When lock relay and remote alarm relay are de-energized.