SECO-LARM USA EVT-PB1-H05Q User Manual

Page of 4
ENFORCER Video, Power and Data Balun with Voltage Booster
 
4
 
                                                        SECO-LARM U.S.A., Inc.
 
 
  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Output voltage is low/high 
 
Check voltage jumper settings 
 
Check output voltage adjustment. 
 
Check input voltage to make sure it meets the input 
requirements 
Green input LED not on 
 
Check input power connections with multimeter to verify 
correct input voltage 
Blue/red output LED not on 
 
Check to see if the load exceeds the maximum limit 
 
Temporarily disconnect power input and output wires for 30 
seconds before connecting 
 
WARRANTY This SECO-LARM product is warranted against defects in material and workmanship while used in normal 
service for a period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is 
limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. 
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, 
repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines 
that such equipment is not operating properly as a result of causes other than defects in material and workmanship. 
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, 
at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential 
personal or property damages of any kind to the purchaser or anyone else. 
 
NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the 
SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right 
to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors. 
Copyright © 2008 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in 
whole or in part, without the written permission of SECO-LARM. 
 
SECO-LARM
®
  U.S.A., Inc. 
16842 Millikan Avenue, Irvine, CA 92606 
 
 
Website: www.seco-larm.com
 
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326  
 
E-mail: sales
@
seco-larm.com
 
 
mi-EVT-PB1-H05Q.docx
 
Troubleshooting: 
PITSW4
 
.docx
 
 
The EVT-PB1-H05Q has a power efficiency rating of 85%. Under typical conditions, the booster will provide sufficient power to 
compensate for long cable runs. The following formulas can be used to determine if enough power is present at the power 
input of the voltage booster: 
1.  Calculate the amount of power measured in Watts: 
 
Voltage  x  Current = Power 
2.  For example, if the voltage is 12VDC, and the current is 750mA: 
 
12VDC  x  .75 = 9 Watts 
3.  Then calculate the amount of power using the voltage booster with the following formula: 
 
Power Input  x Efficiency Rate = Power Output. 
4.  Using the 9 Watts in the previous example, calculate power input of the booster: 
 
9 Watts x .85 = 7.65 Watts 
5.  After the power has been calculated, the output current is calculated from the following formula: 
 
Power  /  Voltage = Current 
6.    Using the example of 9 watts present at the power input, and 7.65 Watts at the power output: 
 
7.65 Watts  / 12VDC = 640mA of available current 
Use Table 3 to determine if additional pairs of Cat5 cable will be needed to transmit power. 
For more information see the Technical Bulletin for the ST-HB105-TTQ at www.seco-larm.com 
 