Heath Zenith 5716 User Manual

Page of 16
D
ual
B
rite
®
Replacement
Sensor Head
Features
•  Turns on lighting when motion is detected.
•  Automatically turns lighting off.
•  Three lamp modes available: Normal, Soft, or Flash.
•  Patented D
ual
B
rite
®
Timer.
•  Photocell keeps the lighting off during daylight hours.
•  LED indicates motion was sensed (day or night).
Requirements
•  Not for use with fluorescent lights.
•  The light control requires 120-volts AC.
•  If you want to use Manual Mode, the control must be
wired through a switch.
Install sensor in accordance with local codes.
© 2007 HeathCo LLC
598-1307-01
Model 5716
OPERATION
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
TEST
TEST  1 5 20
ON-TIME
Off  3  6  Dusk to
   Dawn
D
ual
B
rite
®
Put ON-TIME switch on
the  sensor  bottom  to
TEST and the D
ual
B
rite
®
switch OFF.
D
ual
B
rite
®
 TIMER
Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). Selecting OFF disables this
feature. The motion sensing features will continue to work
as described in this manual. If motion is sensed, the light
turns on full bright for the ON-TIME (1, 5, or 20 minutes)
then returns to dim mode.
LAMP MODES
There are three lamp modes (light turn-on effects) avail-
able when motion is detected:
NORMAL - Light instantly comes on.
SOFT - Light starts dim and gradually increases to full
brightness. Light gradually dims to half-bright, pauses,
and then continues dimming to off when motion is no
longer detected and after selected ON-TIME.
FLASH - Light flashes on then off twice before turning
on full brightness.
MANUAL MODE
ON-TIME
TEST
1 5 20
AUTO
Move ON-TIME Switch to 1, 
5, or 20 minutes
Mode Switching Summary
Flip light switch off 
for one second then 
back on*
MANUAL MODE
AUTO
TEST
*  If you get confused while switching modes, turn the power
off for one minute, then back on. After the calibration
time the control will be in the AUTO mode.
Manual mode only works at night be-
cause  daylight  returns  the  sensor  to
AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the ON-
TIME switch in the 1, 5, or 20 position.
Put the ON-TIME switch in the 1, 5,
or 20 minute position.
... back on.
1 Second OFF
then...
Mode:
On-Time:
Works:
Day
Night
Test
5 Sec
x
x
Normal
1, 5, 20 min.
x
Manual
Until Dawn*
x
Accent
3, 6 Hr. to Dawn
x
LAMP MODE
NORMAL SOFT FLASH
LAMP MODE
Put  the  LAMP  MODE  switch
in  the  Normal,  Soft,  or  Flash
position.