SPECIFICATIONS
Range  . . . . . . . . . . . . .  Up to 60 ft. (18.3 m); [varies with 
surrounding temperature]
Sensing Angle . . . . . . .  Up to 110°
Electrical Load . . . . . . .  Up  to  150  Watts  Maximum 
tungsten
Power Requirements . .  120 VAC, 60 Hz
Operating Modes . . . . .  TEST,  AUTO  and  MANUAL 
MODE
Time Delay  . . . . . . . . .  1, 5, or 10 minutes
Sensitivity  . . . . . . . . . .  Adjustable
Replacement lamp . . . .  T 150W (or less) halogen 120 
VAC 
DESA Specialty Products reserves the right to dis-
continue products and to change specifi cations at any 
time without incurring any obligation to incorporate new 
features in products previously sold.
TEST AND ADJUSTMENT
❒  Turn on the circuit breaker and light switch.
NOTE:  Sensor requires about 1 
1
/
2
 minutes to calibrate 
before it will detect motion. When fi rst turned 
on, wait about 1 
1
/
2
 minutes.
Avoid aiming the control at:
•  Objects that change temperature rapidly, such as 
heating vents and air conditioners. These heat 
sources could cause false triggering.
•  Areas where pets or traffi c may trigger the control.
•  Nearby large, light-colored objects refl ecting light 
may trigger the shut-off feature. Do not point other 
lights at the sensor.
60 ft. 
(18.3 m)
The control is most sensitive to motion across it. 
Motion
Sensor
Motion
❒  Loosen the clamp screw in the 
sensor ball joint and gently 
rotate the sensor to aim.
❒  Walk through the coverage 
area noting where you are 
when the lights turn on. Move 
the sensor head up, down, or 
sideways to change the cover-
age area. Keep the sensor at 
least 1" (25 mm) away from 
the lamps.
❒  Set SENSITIVITY as needed. 
Too much sensitivity may 
increase false triggering.
❒  Secure the sensor head into 
position by tightening the 
clamp screw. Do not over-
tighten the screw.
❒  Set the amount of TIME the 
lights stay on after motion is 
detected. It is selectable from 1, 5, or 10 minutes.
Bottom of Sensor
ON-TIME
10 5 1 TEST
MIN MAX
SENS
8 ft. 
(2.4 m)
110°
❒  Turn the SENSITIVITY (SENS) control to the mid 
position and the ON-TIME control to the TEST 
position.
Aim Sensor 
Down for Short 
Coverage
Aim Sensor 
Higher for Long 
Coverage
Clamp
Ball 
Joint
 Maximum 
Range  Maximum
  
Coverage 
Angle
 
Least Sensitive 
Most Sensitive