•   In the event that the requirements of this 
subdivision can not be met at the time of 
completion of installation, the owner shall have a 
period of thirty (30) days to comply with the 
above requirements; provided, however, that 
during said thirty (30) day period, a battery 
operated carbon monoxide detector with an 
alarm shall be installed.
Approved Carbon Monoxide Detectors: Each carbon 
monoxide detector as required in accordance with 
the above provisions shall comply with NFPA 720 
and be ANSI/UL 2034 listed and IAS certified. 
Signage: A metal or plastic identification plate shall 
be permanently mounted to the exterior of the 
building at a minimum height of eight (8) feet above 
grade directly in line with the exhaust vent terminal 
for the horizontally vented gas fueled heating 
appliance or equipment. The sign shall read, in print 
size no less than one-half (1/2) inch in size, “GAS 
VENT DIRECTLY BELOW. KEEP CLEAR OF ALL 
OBSTRUCTIONS”. 
Inspection: The state or local gas inspector of the 
side wall horizontally vented gas fueled equipment 
shall not approve the installation unless, upon 
inspection, the inspector observes carbon monoxide 
detectors and signage installed in accordance with 
the provisions of 248 CMR 5.08(2)(a)1 through 4.
6.6 Vertical Venting
Vertically vented heaters can be common vented 
 
(up to four heaters).
For vent lengths greater than 5' (1.5 m), 
condensation will form. Insulation is recommended 
and condensation drains may be desired.  Venting 
through the top of the heater cabinet is not 
recommended if vent lengths are longer than 10' 
 
(3 m). In this case, vent from the rear of the heater 
cabinet then run the vent vertically and use a 
condensate drain at the bottom of the vertical vent.
Vent pipe must be sloped 1/4'' (.6 cm) for every 1' (.3 
m).
For 4'' (10 cm), an approved vent cap
 
(P/N 90502102) must be used.
For 6'' (15 cm) common vent, an approved vent cap 
(P/N 90502103) must be used.
For common vertical venting of more than two 
heaters, See Page 18, Figure 11.
A vent shall not extend less than 2' (.6m) above the 
highest point where it passes through a flat roof of a 
building. 
6.7 Length Requirements
If using vent lengths greater than 5' (1.5 m), 
condensation will form in the vent pipe. Insulation 
and additional sealing measures (high temperature 
silicone at all seams) are required. 
The entire vent should be insulated with foil faced 
fiberglass insulation (1/2" thick, 1-1/2# density 
minimum).
6.7.1 Maximum Vent Lengths 
6.8 Vent Material
Vent material may be single wall 26 ga. (minimum) 
galvanized steel or equal thickness stainless steel.  
Completely seal all joints, refer to Page 14, Section 
6.3
.
If penetrating a combustible wall or roof, a listed 
thimble with 2" (5 cm) clearance must be used.  
Where local codes permit, a single section of type 
B-1 vent material may be used at the roof or wall 
penetration instead of a thimble. Ensure vent 
manufacturer's clearance from vent material is 
maintained.  Seal annular space of the type B-1 vent 
as well as all joints in the remaining vent.
6.9 Replacing an Existing Heater in a Venting 
System
When replacing an existing heater in a venting 
system, the venting system may not be properly 
sized to vent the new heater.  The following steps 
must be followed with each appliance connected to 
the venting system placed in operation, while any 
other appliances connected to the venting system 
are not in operation.
1. Seal any unused openings in the venting 
 
system.
2. Inspect the venting system for proper size and 
horizontal pitch, as required by the NFPA 54/
ANSI Z223.1 - latest revision, National Fuel 
Gas Code (US) or Standard CSA B149.1 
Natural Gas and Propane Installation Code 
(Canada) and these instructions.  Determine 
that there is no blockage or restriction, leakage, 
corrosion and other deficiencies which could 
cause an unsafe condition.
3. Close all building doors and windows and all 
doors between the space in which the 
appliance(s) connected to the venting system 
Model UHA[X][S]
30 - 60
Model UHA[X][S]
75 - 125
Number of Elbows
25 ft (7.6 m)
40 ft (12.2 m)
1
20 ft (6.1 m)
35 ft (10.7 m)
2
15 ft (4.6 m)
30 ft (9.1 m)
3
10 ft (3.0 m)
25 ft (7.6 m)
4
5 ft (1.5 m)
20 ft (6.1 m)
5