Enerco ERXL-125 User Manual

Page of 28
22
Enerco | enerRadiant® XL Series Heater
Operating Instructions and Owner’s Manual
 
  Natural outlet pressure should be 3.5”
 
  LP inlet pressure should be 11.0”
 
  LP outlet pressure should be 10.25”
 
  3. Check for proper orifice and air plate.
  Burner Does Not  1. Check ground wire continuity.
 
Stay Lit:  2. Check burner internal wiring for reversed 
leads.
 
  3. Check insulation on the igniter leads.
 
  4. Replace module if necessary.
Honeywell Valve LED Status
The Ener-Radiant XL series Tube Heater is equipped with a honeywell 
Smart Valve. This valve has a built-in diagnostic program, which will 
assist in troubleshooting in the event of a valve-related problem. The 
LED or (Light Emitting Diode) is located on the top of the valve as 
shown in diagram below. The LED status indications are listed below 
to help with the troubleshooting.
FIGURE 22:
OFF 
INDICATED
Off 
No power to the control 
Bright-Dim 
Normal operation.
 
This indication shows whenever the system is  
 
 
powered, unless some abnormal event has occurred.
2-Flashes 
Airflow providing switch remains closed longer than 
30  
 
seconds after call for heat begins (air providing 
switch  
 
stuck closed.)
3-Flashes 
Airflow providing switch remains open longer than 30  
 
seconds after combustion air blower is energized - or  
 
 
blower does not energize.
4-Flashes 
White jumper wire is loose.
5-Flashes 
Flame signal sensed out of proper sequence.
6-Flashes 
System Lockout.
LED