Wayne-Dalton 2411 User Manual

Page of 16
PG. 15
OPERATOR ARM
(SUPPLIED BY OTHERS)
CENTER HINGES
6” WELDED
TRUSS
1/4-20 X 7/8”
TEK SCREWS
OPERATOR ARM
(SUPPLIED BY OTHERS)
1-1/2” X 2-1/4” ANGLE
(CUT TO FIT BETWEEN
STRUT AND CENTER
HINGE)
(SUPPLIED BY OTHERS)
Trolley installation for doors:
< 9’ 2” All Heights
9’ 3” thru 16’ 2” X 10’ 1” (5 sections)
Trolley installation for doors:
16’ 3” thru 19’ 2” over 10’ 1” (5 sections)
19’ 3” thru 24’ 2”
Trolley installation for doors:
9’ 3” thru 16’ 2” over 10’ 1” (5 sections)
16’ 3” thru 19’ 2” X 10’ 1” (5 sections)
STEP 14: INSTALLING THE INSIDE SIDE LOCK:
Attach the inside side lock using (4) 1/4” - 20 x 5/8”
Tek screws as shown in Fig. O
FIG. O
OPERATING ZONE
You Can Save Time And Effort If  You First Establish All The Facts About
The “Operating Zone”
The “ Operating Zone” is the area surrounding the door opening, extending upward and backward as far as the door will
travel. We call it the Operating Zone because it is the area that the door will have to operate within and the dimensions are
critical and must be known in advance of a door and operator installation.
1. Daylight Opening; Exact size of finished opening
2. Sideroom; required distance from the door opening to a wall or any obstruction. Refer To Sideroom Chart
3. Headroom;
 required distance from top of  door opening to the ceiling or underside of  joists. Refer To Headroom Chart
4. Backroom;
 required distance from door opening header to the furthest back point to which the door track or operator unit, and their
brackets, will extend.
PG. 2
HEADROOM  CHART For Standard Lift Track
 
(Minimum Distance Required)
Dim. Y INDICATES THE DISTANCE FROM THE HEADER TO THE CENTER LINE OF TORSION SHAFT.
NOTE: 2 1/2” OF ADDITIONAL HEADROOM IS REQUIRED FOR SINGLE TROLLEY OPERATOR INSTALLATIONS.
STEP 1.  Verify The OPERATING ZONE Dimensions
               A - Exact size of  finished daylight opening.  Do you have the correct door size?
               B - Sideroom requirements for track and spring shaft.  (Refer to sideroom chart)
               C - Headroom requirements.  (Refer to headroom chart)
               D - Backroom ( depth into room )  Manual lift = Door height plus 18”  Operators  = Door height plus 48”
               E - Jambs must be plumb and solidly attached to the building.  Floor must be level or exact gradeline established before
                     you start.
STEP 2.  Shipping tags show important information, door size, track size and type, spring size and hardware type.
               Verify that all material is present before attempting installation.
Dual Trolley installation
for doors over 24’ 2”
wide X any height.
CENTER HINGES
OPERATOR ARM
(SUPPLIED BY
OTHERS)
8” EXTENSION
(REQUIRED TO CLEAR
WELDED TRUSS)
(2) 1/4-20 X 7/8” TEK SCREWS
PER CORNER
OPERATOR BRACKET
8” WELDED
TRUSS SHOWN
1-1/2” X 2-1/4” ANGLE
(SUPPLIED BY OTHERS)
ATTACH TO EACH STILE WITH
(2) 1/4-20 X 7/8” TEK SCREWS
OPERATOR ARM
(SUPPLIED BY OTHERS)
1/4-20 X 7/8”
TEK SCREWS
8” EXTENSION
(REQUIRED TO CLEAR
WELDED TRUSS)
8” EXTENSION
(REQUIRED TO
CLEAR WELDED
TRUSS)
38 in. operator bracket
and dual trolley brackets
are optional for doors
19’ 3” thru  24’ 2” wide.
HEADROOM
“A”
“B”
SIDE ROOM
DAYLIGHT
OPENING
HEIGHT
BACKROOM
DAYLIGHT
OPENING
WIDTH
SIDE ROOM
TRACK
DEPTH
SIZE
INTO
ROOM
STEEL
and
WOOD
SOLID
TUBE
MASONRY
DOOR HEIGHT
PLUS 18"
DOOR HEIGHT
PLUS 24"
DIM. A
DIM. B
SIDEROOM
SIDEROOM
TRACK
TORSION SHAFT
2"
2-1/2"
3-1/2"
10"
5"
5"
3"
3"
5"
10"
3 "   T R A C K
2 "   T R A C K
2 "   T R A C K
1 5 "   R A D I U S
1 5 "   R A D I U S
1 2 "   R A D I U S
4 0 0 - 8
H E A D R O O M
1 5   1 / 2 "
1 5 "
1 2 "
4 0 0 - 1 2
D I M   Y
1 3 "
1 2   1 / 2 "
9   1 / 2 "
H E A D R O O M
1 7   1 / 2 "
1 7 "
1 4 "
D I M   Y
1 4   1 / 2 "
1 4 "
1 1 "
H E A D R O O M
2 1 "
2 0   1 / 2 "
N A
D I M   Y
1 6   1 / 2 "
1 6 "
N A
H E A D R O O M     C H A R T
F o r   S t a n d a r d   L i f t   T r a c k   ( M i n i m u m   D i s t a n c e   R e q u i r e d )
D R U M S
D I M S
5 2 5 0 - 1 8