Essick Air M301A User Manual

Page of 11
4
110522-1
 Problem 
Possible Cause 
Remedy
Failure to 
start or no air 
delivery
Inadequate 
air delivery 
with cooler 
running
Inadequate 
cooling
1.  No electrical power to 
unit
 • 
Fuse 
blown
 • 
Circuit 
breaker 
tripped
 
•  Electric cord un-
plugged or damaged
2.  Belt too loose or tight
3. Motor overheated
 
•  Belt too tight
 
•  Blower bearings dry
4. Motor locked
1. Insuffi cient air exhaust
2.  Belt too loose
3. Pads plugged
1.  Inadequate exhaust in 
house
2.  Pads not wet
 • 
Pads 
plugged
 
•  Open spots in pads
 • 
Trough 
holes 
clogged
 
•  Pump not working 
properly
1. Check power
 • 
Replace 
fuse
 • 
Reset 
breaker
 
•  Plug in cords or 
replace if damaged
2.  Adjust belt tension
3.  Determine cause of 
overheating
 
•  Adjust belt tension
 
•  Oil blower bearings
4. Replace motor
1.  Open windows or 
doors to increase air 
fl ow
2.  Adjust belt tension or 
replace if needed
3. Replace pads
1.  Open windows or 
doors to increase air 
fl ow
2. Check water distribu-
tion system
 • 
Replace 
pads
 • 
Repack 
pads
 
•  Clean trough and 
unplug holes
 
•  Replace or clean 
pump 
Troubleshooting
Motor cycles 
on and off
Noisy
Excessive 
humidity in 
house
Musty or 
unpleasant 
odor
Water drain-
ing from 
cooler
1. Low voltage
2.  Excessive belt tension
3.  Blower shaft tight or 
locked
4. Bearings dry
1. Bearings dry
2.  Wheel rubbing blower 
housing
3. Loose parts
1. Inadequate exhaust
1.  Stale or stagnate water 
in cooler
2.  Pads mildewed or 
clogged
3.  Pads not wetting 
properly
 • 
Trough 
holes 
clogged
 
•  Pump not working 
properly
1.  Float arm not adjusted 
properly
2.  Drain assembly leak-
ing
1. Check voltage
2.  Adjust belt tension
3.  Oil or replace bear-
ings
4. Oil bearings
1. Oil bearings
2. Inspect and realign
3.  Tighten loose parts
1.  Open doors or win-
dows
1.  Drain pan and clean 
pads
2. Replace pads
3. Check water distribu-
tion system
 • 
Clean
 
•  Replace or clean 
pump 
 
1. Adjust fl oat
2.  Tighten nut and drain 
cap.
 Problem 
Possible Cause 
Remedy
Model
Modelo
Volts
Voltios
Amperage
Ameraje
Speed
Velocidad
Water Capacity (gal)
Capacidad de Agua (galón)
Weight (lbs.)
Peso (libras)
Dry
Seco
Operating
Lleno
M201A
115
4.7
2
4.8
62
102
M301A / RM301A
115
7.9
2
9.2
107
184
M401A / RM401A
115
10.5
2
11.3
169
263
Specifi cations  /  Especifi caciones