The beacon II™ Refrigeration System is a preassembled, factory installed refrigeration 
system featuring an integrated microcomputer based electronic control board.
The beacon II™ Refrigeration System replaces the expansion valve, solenoid valve, room 
thermostat, defrost control and timer. It comes factory preset thereby eliminating all 
of the expensive and time consuming fine tuning and adjustments necessary for a good system installation. For 
additional information, contact your Sales Representative.
The Bohnmizer
®
 System
The bohnmizer® system is a complete factory furnished commercial refrigeration split system designed to operate 
properly regardless of climatic conditions.  As the ambient temperature falls below 75°F, the head pressure is 
allowed to decrease in direct relationship to the ambient.
The heart of the system is the bohnmizer valve, whose design allows the proper amount of refrigerant to flow to 
the evaporator irrespective of the valve inlet pressure.  The bohnmizer valve also responds very rapidly to changes 
in suction temperature, which assures the maintenance of low superheat, regardless of the ambient temperature.
The bohnmizer system concept results in operational energy savings, increased compressor life, reduced 
refrigerant costs and less maintenance expense.
Options
Electrical options:
Outdoor
Indoor
Stock
Smart Defrost Kit™ 
Option
Option
n/A
Dual pressure control (not available on beacon II™)
Option
Option
n/A
Adjustable low pressure control for medium temp. comp.
Option
Option
n/A
Crankcase heater
Standard
n/A
Standard
Fused disconnect / non-fused disconnect
Option
Shipped loose
n/A
Phase loss / low voltage monitor
Option
Option
n/A
Fixed fan cycling — pressure or temperature (2 fan units) 
(Pressure standard on beacon II™)
Option
Option
n/A
Air or electric defrost timer only
Option
Option
1/2-3 HP low temp.
Electric defrost with timer & contactors (040-060 models only)
Option
Option
4-6 HP low temp.
beacon II™
Option
Option
n/A
Mechanical options:
Head pressure control flooding valve
Standard
Option
Standard
Liquid line drier, sight glass
Option
Option
Standard
Suction line filter
Option
Option
n/A
Suction accumulator (standard on X6 models)
Option
Option
n/A
Oil separator with discharge line check valve (D cabinet)
Option
Option
n/A
Liquid line solenoid valve and pumpdown switch
Option
Option
n/A
Replaceable core liquid line filter (D cabinet)
Option
Option
n/A
Replaceable core suction line filter (D cabinet)
Option
Option
n/A
Precharged refrigerant with line sets and wire harnesses
Option
Option
n/A
Oversize receiver (D cabinet)
Option
Option
n/A
Low ambient kit with heated and insulated receiver, TD relay
Option
n/A
n/A
12" Extended legs for snowbelt operation
Shipped loose
Shipped loose
Shipped loose