Air King 9520 Leaflet

Page of 2
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.  PROTECT YOUR-
SELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.  FAILURE TO COMPLY WITH 
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!  
 
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
20" I-BEAM MOUNT FAN
20" (50.8 cm) MODEL 9520
OPERATING INSTRUCTIONS & PARTS MANUAL
DESCRIPTION
The Air King
®
 20" (50.8 cm) I-Beam mount fan features 3-speed pull cord 
operation and a 3-paddle fan blade. This fan has a permanently lubricated 
motor  with  a  9  ft.  (2.74  m)  18/3  cord  set  and  is  constructed  of  sturdy, 
powder coated steel.
SPECIFICATIONS
Motor  ...................................... 120 V, 50/60 Hz 
Blade diameter ........................ 20" (50.8 cm) Model 9520
Speeds .................................... 3
Control..................................... Pull Cord
Air flow distribution .................. 360°
Approvals................................. UL/ETL Listed. Close mesh fan guard
                                                   meets OSHA requirements.
....................
GENERAL SAFETY INFORMATION
1.  Make  certain  that  the  power  source  conforms  to  the  electrical 
requirements of the fan.
2.  The  power  cord  is  equipped  with  a  three-prong  grounded  plug  that 
must be inserted into a matching receptacle. Under no circumstances 
should the grounding prong be cut off the plug. Where a two-prong wall 
receptacle is encountered, it must be replaced with a properly grounded 
three-prong receptacle installed in accordance with the National Electrical 
Code (NEC) and all applicable local codes and ordinances. This work 
must be done only by a qualified electrician, using copper wire only.
WARNING:  USE OF A THREE-PRONG TO TWO-PRONG ADAPTER IS 
NOT RECOMMENDED. IMPROPER CONNECTION MAY CREATE THE 
RISK OF ELECTRICAL SHOCK.  USE OF SUCH ADAPTERS IS NOT 
PERMITTED IN CANADA.
3.  Where possible, avoid the use of extension cords.  If they must be used, 
minimize the risk of overheating by ensuring that they are UL listed and 
of the proper gauge and length. Never use a single extension cord to 
operate more than one fan.
4.  Do not insert fingers or foreign objects into the fan. Do not block or 
tamper with the fan in any manner while it is in operation. Do not touch 
the fan while in operation or just after it has been turned off, as some 
parts may be hot enough to cause injury.
5.  Unplug power cord before installing or servicing the fan.
WARNING:  DO NOT DEPEND UPON THE ON-OFF SWITCH AS THE 
SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING OR 
SERVICING THE FAN.  ALWAYS UNPLUG THE POWER CORD.
6.  This  fan  is  intended  for  general  use  ONLY.  It  must  NOT  be  used  in 
potentially dangerous locations such as flammable, explosive, chemical 
laden or wet atmospheres.
7.  DO NOT mount fan near windows or bay doors.  Rain may create an 
electrical hazard.
8.  Completely  reassemble  fan,  according  to  instructions  before 
reconnecting to power supply. 
WARNING:
  TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE 
THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICE.
WARNING:
 THIS PLUG IS A SAFETY FEATURE, TO REDUCE THE RISK OF 
FIRE, ELECTRIC SHOCK AND PERSONAL INJURY. DO NOT REMOVE, REPLACE, 
REPAIR OR TAMPER WITH THE ORIGINALLY SUPPLIED PLUG. IF THE FAN DOES 
NOT FUNCTION PROPERLY, IT MAY BE DUE TO THE SAFETY DEVICE INCOR-
PORATED IN THIS PLUG. RETURN TO AN AUTHORIZED SERVICE CENTER 
OR CALL 800-233-0268, MONDAY - FRIDAY, BETWEEN 8:00 A.M. AND 5:00 
P.M. EST. IF THE PLUG WARNING LABEL IS MISSING OR DAMAGED, CALL 
THE TOLL FREE NUMBER FOR A REPLACEMENT LABEL.
   
MODEL                     9520
    SPEED    HIGH         MED          LOW
     CFM        7510           5010          3735
     M
3
/s         3.54            2.36           1.76
     RPM        1560           1041          776
     Amps       1.78            1.46           1.02
     Watts        207            167            115
     dB A         62              55              48
WARNING:  BECAUSE OF SIZE AND WEIGHT OF THIS FAN, MAKE 
SURE ALL PARTS ARE COMPLETELY ASSEMBLED ACCORDING TO 
INSTRUCTIONS. FAILURE TO DO SO COULD RESULT IN FAN COMING 
APART DURING OPERATION AND/OR PERSONAL INJURY.
I-BEAM MOUNT  INSTALLATION
1.  Locate the L-shaped pipe to the desired location on the I-Beam flange. 
Install the 5/16 x 2" U-Bolt over the pipe and through the clamping plate 
holes. The flat part of the clamping plate fits on the I-Beam flange and 
the end with the slight bend goes against the pipe. Install flat washer, 
lock washer and nuts. Finger tighten the nuts on the U-Bolt. (Figure 1)
2.  Slide  the    clamping  plate  onto  I-Beam  flange  until  U-Bolts  contact 
flange.
3.  Adjust L-shaped pipe so forward clamp plate is as close to the label 
at the bend as possible.
4.  Tighten nuts on bolt so pipe does not move.
5.  Screw on the adapter mount as far as it will go on to the L-shaped 
pipe. Tighten set screw in pipe coupling with provided allen key.
6.  Align Yoke with grill mounting threads. Loosely attach one Grill Knob 
and one Rubber Spacer to the Head Assembly. Attach the other Grill 
Knob and Rubber Spacer to the Head Assembly  and  FIRMLY tighten. 
Return to the first Grill Knob and FIRMLY tighten. 
(Figure 2)
1
5084037
Rev. A 9/07
5/16 Nut
5/16 Lock 
Washer
5/16 Flat 
Washer
1/4" Set Screw
Tighten
 Bolt
Yoke
Fan Head
Figure 1
U-Bolts
Tighten Clamp 
Plate Here
9.  This Fan is not suitable for use in hazardous locations. Please refer to 
National Electric Code (NEC) Article 500 or applicable state or local 
codes or standards relating to electrical requirements for Hazardous 
locations. 
THIS FAN DOES NOT MEET THE REQUIRMENTS OF 
NEC ARTICLE 500 (2002).
Commerical Style Fan
WARNING
:
 This fan should be used only in a clean, dry 
environment. Mounting of this product in any way other then 
specified in the instruction sheet will null and void the 
manufacturer's warranty
.