Air King 4CH68G User Manual

Page of 4
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT 
DESCRIBED.  PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.  FAILURE TO COMPLY 
WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
 RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.  
1
2084007
Rev. P 6/07
20" DELUXE PIVOT FAN
MODEL 4CH68G/9500G
OPERATING INSTRUCTIONS & PARTS MANUAL
8
2084007
Rev. P 6/07
SPECIFICATIONS
Motor  .................................120V, 60 Hz
Blade diameter ...................20" ( 50.8 cm)
Speeds ...............................3
Control................................Rotary Switch
Air flow distribution .............120°
Approvals............................UL Listed. Close mesh fan guard 
                                            meets OSHA requirements.
DESCRIPTION
The Air King 20" (50.8 cm) Deluxe Pivot Fan features 3 speed whis-
per-quiet  operation,  a  5-paddle  fan  blade,  and  120°  adjustable  tilt.  
The fan has a permanently lubricated motor with a 6 ft. (1.8 m) 18/3 
cord set.
   
MODEL            4CH68G/9500G
    SPEED    HIGH         MED          LOW
     CFM        2470           2055          1570
     M
3
/s         1.17            0.97           0.74
     RPM        1137           1018          777
     Amps       1.05            0.82           0.62     
     Watts       129             106            79
     dB A         64              60              52
GENERAL SAFETY INFORMATION
When  using  electrical  appliances,  basic 
precautions  should  always  be  followed  to 
reduce the risk of fire, electric shock and injury 
to person, including the following:
1.  Read all instructions before using Fan.  
2.  Make certain that the power source conforms to the electrical 
requirements of the Fan.
3.  Use this Fan only as described in this manual.  Any other use 
not recommended by the manufacturer may cause fire, electrical 
shock, or injury to persons.
4.  Unplug power cord before installing, servicing, or moving the Fan.
WARNING: DO NOT DEPEND UPON THE ON-OFF SWITCH AS 
THE  SOLE  MEANS  OF  DISCONNECTING  POWER  WHEN 
INSTALLING OR SERVICING THE FAN.  ALWAYS UNPLUG THE 
POWER CORD.
5.  This  Fan  must  NOT  be  used  in  potentially  dangerous 
locations  such  as  flammable,  explosive,  chemical-laden 
or wet atmospheres.
6.  DO  NOT  use  Fan  in or near a window.  Rain may create an 
electrical hazard.
7.  The power cord is equipped with a three-prong grounded plug 
that must be inserted into a matching receptacle.  Under no 
circumstances  must  the  grounding  prong  be  cut  off  the  plug.  
Where a two-prong wall receptacle is encountered, it must be 
replaced with a properly grounded three-prong receptacle installed 
in accordance with the National Electrical Code (NEC) and all 
applicable local codes and ordinances.  This work must be done 
only by a qualified electrician, using copper wire only.
WARNING:
 USE OF A THREE-PRONG TO TWO-PRONG 
ADAPTER  IS  NOT  RECOMMENDED.    IMPROPER 
CONNECTION  MAY  CREATE THE  RISK  OF  ELECTRO-
CUTION.  USE OF SUCH ADAPTERS IS NOT PERMITTED 
IN CANADA.
WARNING:
 THIS  PLUG  IS  A  SAFETY  FEATURE. TO 
REDUCE THE  RISK  OF  FIRE,  ELECTRIC  SHOCK  AND 
PERSONAL INJURY, DO NOT REMOVE, REPLACE, REPAIR 
OR TAMPER WITH THE ORIGINALLY SUPPLIED PLUG. IF 
THE FAN DOES NOT FUNCTION PROPERLY, IT MAY BE 
DUE TO THE  SAFETY  DEVICE  INCORPORATED  IN THIS 
PLUG. CONTACT YOUR GRAINGER DISTRIBUTOR.
8.  Where possible, avoid the use of extension cords.  If they must       
be used, minimize the risk of overheating by ensuring that they 
are UL listed.  Never use a single extension cord to operate more 
than one Fan.
9.  Do not operate any Fan with a damaged cord or plug or after the 
Fan malfunctions, has been dropped or damaged in any manner.  
Return Fan to authorized service facility for examination, electrical 
or mechanical adjustment or repair.
10.Do  not  insert  or  allow  fingers  or  foreign  objects  to  enter  any 
ventilation or exhaust opening as it may cause an electric shock 
or fire, or damage the Fan.  Do not block or tamper with the Fan 
in any manner while it is in operation. 
11.Always place the Fan on a stable, flat, level surface when operating, 
to avoid the chance of the Fan overturning.  Locate the Power Cord 
so the Fan or other objects are not resting on it.  Do not run Power 
Cord under carpeting.  Do not cover Power Cord with throw rugs, 
runners, or the like.  Arrange Power Cord away from room traffic 
and where it will not be tripped over.
12.This Fan is not intended for use in wet or damp locations.  Never 
locate a Fan where it may fall into a bathtub or other water container.
13. Do not use Fan outdoors.
14.This Fan is not suitable for use in agricultural facilities including 
areas  where  livestock,  poultry  or  other  animals  are  confined. 
Please refer to National Electric Code (NEC) Article 547-7 (2002), 
or applicable state or local codes or standards relating to electrical 
requirements  for  Agricultural  Buildings. 
THIS  FAN  DOES  NOT 
MEET THE REQUIRMENTS OF NEC ARTICLE 547-7 (2002).
15.This Fan is not suitable for use in hazardous locations. Please refer to 
National Electric Code (NEC) Article 500 or applicable state or local 
codes or standards relating to electrical requirements for Hazardous 
locations. 
THIS FAN DOES NOT MEET THE REQUIRMENTS OF 
NEC ARTICLES 500 (2002)
WARNING:
 REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK 
–  DO  NOT  USE THIS  FAN WITH  ANY  SOLID  STATE  SPEED 
CONTROL DEVICES.
SAVE THESE 
INSTRUCTIONS
This Fan is not intended to be used in 
commercial, industrial or agricultural settings.
MODEL /MODELO/ MODÉLE   4CH68G/9500G