Gianni Industries Easiprox User Manual

Page of 4
 
Copyright © Gianni Industries, Inc. All Rights Reserved. 
P-MU-EASIPROX  Ver. B  Published on 2008.02.12                                                                          Page: 3/ 4
 
V. Operation 
Instruction 
WARNING:
 Please read all of operation instruction before proceeding. 
 
„
  Setting Master Card 
If the GREEN and YELLOW lamps are flashing, it indicates that the memory is empty and 
that there is no Master Card. All programming is done by using this Master Card. 
 
„
 Add 
Cards 
Read the Master Card once→ Only the GREEN lamp wills light→ Wait for the GREEN 
lamp to start flashing→ The Easiprox is now in the ADD state. 
In this state every Card presented to the Easiprox will operate the relay and be added to 
memory. Read the Master Card to return to the Stand-by state. 
 
„
 Delete 
Cards 
Read the Master Card twice with a time between reads of less than 2 seconds→ The 
RED lamp will light→ Wait for the RED lamp to start flashing→ The Easiprox is now in 
the DELETE state. 
In this state every Card that is presented to the reader will be deleted from the system 
memory. (Cards can now also be deleted by using the optional Card Simulator.). Once 
the Card or a group of Cards have been deleted, read the Master Card to return to the 
Stand-by state. 
 
„
 Clear 
Memory 
Read the Master Card three times with a time between reads of less than 2 seconds→ 
The YELLOW and RED lamps will light→ Wait for the YELLOW and RED lamps to start 
flashing→ The Easiprox is now in the CLEAR MEMORY state.  
Now present any Card except the Master Card to the reader and all memory will be 
cleared. Alternatively, read the Master Card to abort this function. Once the memory is 
cleared the YELLOW and GREEN lamps will flash to indicate that the memory is empty. 
 
„
 Totally 
reset 
Power off→ Shorted the Clear Memory (Black cable)→ Power on→ Wait for the 
YELLOW and RED lamps to start flashing(remove the black cable)→ Once the 
memory is cleared the YELLOW and GREEN lamps will flash to indicate that the memory 
is empty. 
 
„
 Time 
Adjust 
This function sets the relay operating time for a push-button input and a valid card read.  
Read the Master Card 4 times with a time between reads of less than 2 seconds→ All 
the lamps will go off→ Wait for the YELLOW lamp to start flashing→ The Easiprox is 
now in the TIME ADJUST state and each flash of the YELLOW lamp equates to 0.7 
second of relay operation time.  
Once the desired time is reached (max 42 seconds), read the Master Card to store the 
time and return to the Stand-by state.  If programming mode is required simply allow the 
YELLOW lamp to flash until it stops automatically (after 61 flashes).  The unit will now be 
in programming mode.