Gianni Industries DG-11 Leaflet

Page of 2
 
Copyright Gianni Industries, Inc. All Rights Reserved.  
P-MU-DG10-4C  Ver. A  Publish:2004.09.07                                                             Page: 1/ 2
 
 
The Digital Keyless Entry System (4 digit) 
Operation User's Manual
 
 
DG-11 
(Mount)
DG-12
 
(Mount/ANSI size)
DG-10 
(Surface Mount)
ANSI Box
 
 
I. Features: 
‹
 
4 digit codes  
‹
 
Door Reed Switch Input for Anti-Trailing 
‹
 
10 user PINs 
‹
 
Fully Programmable via keypad and master code 
‹
 Non-Volatile 
Memory 
 
‹
 
Invalid PIN Lock-out 
 
II. Specifications: 
‹
 
Operating Voltage: 9~14 Vdc 
‹
 
Current Draw: Average 30mA, Peak 80mA @ 12Vdc  
‹
 
Input: One request-to-exit, and time out reed switch  
‹
 
Relays: N.O./N.C./Com. Output (free voltage contact), 3A@ 125Vac or 30Vdc 
‹
 
Case Material: ABS (UL94V0) 
‹
 Operating 
Temperature:-20~+70℃ 
‹
 
Ambient Humidity:0~95% relative humidity non-condensing 
‹
 Visual 
Signals: 
„
 
Green: Power on 
„
 
Red: Relay activated 
„
 
Yellow: Program Mode、Lock-out 
‹
 
Factory Master Code: 1234 
‹
 
Invalid PIN Lockout: System will shut down 60 seconds while 6 times of incorrectly 
password attempted. 
‹
 
Relay Activation Time: (*20) 
„
 Pulse 
mode:1~99 seconds(01~99) 
„
 Latching 
mode(00) 
‹
 
EPROM: Non-volatile memory, System will retain all programs and codes after a total   
loss of power. 
‹
 User 
PINs: 
(*
01~*10)It is possible to program 10 different user PIN codes.