Gianni Industries DG-12S Leaflet

Page of 1
GIANNI INDUSTRIES, INC.
Copyright 2008 Gianni industries, inc. All rights reserved.
DM-CA-DG-12 Ver. E Published on 2008.08.04
The products are manufactured under an ISO
9 0 0 1
Q C
0 8 0 0 0 0
C e r t i f i e d
Q u a l i t y
Management Program environment back its
product quality, performance and commitment
to customer satisfaction.
&
Features
Statement
DG-12
Digital Keyless Entry System
The product is warranted against defects in material and
workmanship while used in normal service for a period of 1
year from the date of sale to the original customer. The GEM
policy is one of continual development and improvement;
therefore GEM reserves the right to change specifications
without notice.
Warranty
Unit: mm
Specifications
4 digit codes
Door Reed Switch Input for Anti-Trailing
Durable Stainless Steel Faceplate
10 user PINs
Fully Programmable via keypad and master code
Non-Volatile Memory
Invalid PIN Lock-out
Optional With Luminous Keypad
Digital code-operated for indoor access control keypad with
up to 10 individual user PIN codes , suitable for small and
m e d i u m - s i z e b u s i n e s s e s , m u l t i - t e n a n t r e s i d e n t i a l a n d
commercial buildings, as well as clinics and health facilities.
The door reed switch Input is used to time out the timer
when door is moved for Anti-Trailing. User access PINs
ensure that all functions controlled to authorized persons
only. It mounts to ANSI
lectrical box or directly to
any wall.
Logical memory can prevents unauthorized persons
from gaining PIN code entry by trial and error, host will shut
down 60 seconds while 6 times of incorrectly password
applied which would eliminate any random application of card
ID code transmission.
single-gang e
Operating Voltage: 9~14 Vdc
Current Draw: Average 30mA, Peak 80mA @ 12Vdc
Input: One request-to-exit, and time out reed switch contact
Relays: N.O./N.C./Com. Output (free voltage contact), 3A@
125Vac or 30Vdc
Ambient Humidity:0~95% relative humidity non-condensing
Visual Signals:
Green: Power on
Red: Relay activated
Yellow: Program Mode Lock-out
Factory Master Code: 1234
Invalid PIN Lockout: System will shut down 60 seconds while
6 times of incorrectly password attempted.
Relay Activation Time:(*20)
Pulse mode: 1~99 seconds(01~99)
Latching mode (00)
EPROM: Non-volatile memory, System will retain all
programs and codes after a total loss of power.
User PINs: (*01~*10)It is possible to program 10 different
User PIN codes.
Operating Temperature:-20~+70C
(Flush Mount Installation)
DG-12S
DG-12S
DG-12
(Surface Mount)
(Flush Mount)
DG-12
1
1
4
4
7
7
2
2
5
5
8
8
0
0
3
3
6
6
9
9
ANSI single
gang electrical box
Unit: mm
Unit: mm
70
116
34
No. 13, Zhong Sing Road, Tu-Cheng Industrial Zone,
Tu-Cheng City, Taipei, Taiwan 23678
Tel: 886-2 2267 7986 / Fax: 886-2 2267 9876
E-Mail: info@gianni.com.tw
Website: gianni.tw