All installations and services must be performed by qualified service personnel. 
III.  GENERAL INSTRUCTIONS AND CLEARANCES – READ BEFORE START OF  
INSTALLATION 
 
1.  The BTU output capacity of the furnace proposed for installation should be based 
on a heat loss calculation made according to the manuals provided by the Air 
Conditioning Contractors of America (ACCA) or the American Society of Heating, 
Refrigeration and Air Conditioning Engineers, Inc. (ASHRAE). 
 
2.  This furnace is equipped with orifices sized for operation with natural gas.  For 
conversion to Propane Gas see instruction MG-815  in Gas Conversion Kit 
AOPS7743. 
 
3.  These Category Type IV furnaces are shipped completely assembled and wired 
(internally). See the Dealer Receiving and Freight Claim Procedure  Section of the 
price guide for parts shortage or damage. The furnace and duct system must be 
adjusted to obtain a temperature rise of 40°F to 70°F through the furnace after 
installation. For the Energy Star Eco Tech models the temperature rises are 40°F to 
70°F for the 50 series and 50°F to 80°F for the 75 series. (See rating label located 
on separator panel inside the furnace vestibule). The installation must conform with 
local codes, or in the absence of local codes, with the National Fuel Gas Codes 
(ANSI Z223.1 or latest edition) and with these instructions. 
 
: This furnace is not to be used for temporary heating of buildings or 
structures under construction. 
 
Many of the chemicals used during construction, when burned, form acid bearing 
condensate that can substantially reduce the life of the heat exchanger. 
 
4.  It is recommended that a commercially available CO alarm be installed in 
conjunction with any fossil fuel burning appliance.  The CO alarm shall be installed 
according to the alarm manufacturer’s installation instructions and be listed in 
accordance with the latest edition of the UL Standard for Single and Multiple Station 
Carbon Monoxide Alarms, UL 2034, or the CSA International Standard, Residential 
Carbon Monoxide Alarming Devises, CSA 6.19. 
 
5.  The installer shall be familiar with and comply with all codes and regulations 
applicable to the installation of these heating appliances and related equipment.  In 
lieu of local codes, the installation shall be in accordance with the current provisions 
of one or more of the following standards. 
 
a.  Federal Manufactured Home Constructions & Safety Standard (H.U.D. Total 
24, Part 280.) 
b.  American National Standard (ANSI-119.2/NFPA-501C) for all recreational 
vehicle installations. 
c.  American National Standard (ANSI-Z223.1/NFPA-54) for all gas-fired 
furnaces. 
 