IF LED LIGHT FLASHES:
1 FLASH, THEN PAUSE         SYSTEM LOCKOUT
2 FLASHES, THEN PAUSE     PRESSURE SWITCH STUCK CLOSED
3 FLASHES, THEN PAUSE     PRESSURE SWITCH STUCK OPEN
4 FLASHES, THEN PAUSE     OPEN LIMIT SWITCH OR ROLLOUT SWITCH
6 FLASHES, THEN PAUSE     115 VOLT AC POWER REVERSED
7 FLASHES, THEN PAUSE     LOW FLAME SENSE SIGNAL
8 FLASHES, THEN PAUSE     CHECK IGNITOR OR IMPROPER GROUNDING
CONTINUOUS FLASHING       FLAME HAS BEEN SENSED WHEN
                     (NO PAUSE)       NO FLAME SHOULD BE PRESENT
                                               (NO CALL FOR HEAT)
                                               CHECK COMPLETE SYSTEM OUT.
THE LED WILL ALSO FLASH ONCE AT POWER-UP.
LED LIGHT STAYS ON CONTINUOUSLY,
COMPLETE FAILURE - REPLACE
INTEGRATED CONTROL.
 