Johnson Controls TM9V100C20MP11 Leaflet

Page of 2
NOTES:
1.
If the furnace is equipped with NOx screens and is to be
used with LP (propane) gas, the screens must be removed
prior to start-up.
2.
Drip leg in the gas line must be installed.
3.
The furnace controls require correct polarity on the power
supply and a proper ground.
4.
Y & G must be connected to the control board for cooling
operation.
5.
External filters are required on all configurations.
6.
Electrical or gas entry is available on both casing sides.
7.
To measure total static pressure, add supply duct pressure
to the return duct pressure, add pressure drop across the ‘A’
coil, and add pressure drop across the filter. Ignore negative
signs on the readings.
8.
Inlet gas pressure should be 7” w.c. for natural gas and  11”
w.c. for propane. Nominal manifold gas pressure is 3.5” w.c.
for natural gas and 10” w.c. for propane at max. input.
9.
For downflow application the vent blower must be rotated 90
left or right as shown.
 Other airflows are available. see Tech Guide for all CFM options.
* Cool Tap.
** Adjustment Tap.
LED INDICATOR
Slow Green Flash - Normal operation in standby mode.
Slow Amber Flash - Normal operation with call for cooling.
Two Amber Flashes - Normal operation with call for heat.
Three Amber Flashes - Normal operation, burner is on at end of
thermostat cycle.
Six Amber Flashes - Normal operation with call for heat pump
heating.
Any Red Flash - Fault condition. NOTE: 4 or 5 flashes may indi-
cate a blown fuse on the circuit board.
Models
Airflow CFM (Bottom Return without Filters)
Minimum Wire
Size awg @ 75'
One-Way
Maximum
Over Current
Protection
0.5" ESP (Nominal)
*D-A**
*C-A**
*B-A**
*A-B**
TM9V060B12MP11
600
690
1000
1305
14
15
TM9V080B12MP11
600
680
1000
1290
14
15
TM9V080C16MP11
850
905
1175
1670
14
15
TM9V100C16MP11
870
910
1160
1655
14
15
TM9V100C20MP11
960
1155
1605
2215
12
20
TM9V120D20MP11
960
1160
1595
2180
12
20
Models
Input 
Rate
Total Unit
Amps
Air Temp. Rise
Max Input °F
Air Temp. Rise
Min Input °F
Time For 1 ft
3
 Natural Gas  
(1030 Btu/Ft
3
) Seconds 
(On Max. Rate)
Max
Min
TM9V060B12MP11
60,000
21,000
9
35 - 65
35 - 65
62
TM9V080B12MP11
80,000
28,000
9
35 - 65
30 - 60
46
TM9V080C16MP11
80,000
28,000
12
35 - 65
35 - 65
46
TM9V100C16MP11
100,000
35,000
12
35 - 65
30 - 60
37
TM9V100C20MP11
100,000
35,000
14
35 - 65
35 - 65
37
TM9V120D20MP11
120,000
42,000
14
35 - 65
35 - 65
31
This document does not replace the installation instructions, which must be referred to for 
detailed information.
CLEARANCES
* 24" clearance in front and 18" on side recommended for 
service access.
All furnaces approved for alcove and attic installation.
DIMENSIONS
SUPPLY END
RETURN END
LEFT SIDE
Combustion Air Inlet
Condensate Drain
(Downflow)
Vent Connection
Outlet
Thermostat
Wiring
29.5”
28.5”
RIGHT SIDE
Condensate Drain
(Downflow)
14”
1”
1.5”
23”
Combustion Air Inlet
Gas Pipe
Entry
Electrical
Entry
Condensate
Drain
Optional Return Air
Cutout (Either side)
FRONT
A
33”
Clips can be flipped
into the up position
for coil cabinet or
plenum attachment
A-COIL
Follow all national and local codes and standards in addition to this document.
The installation must comply with regulations of the serving gas supplier, local building,
heating, plumbing, and other codes. In absence of local codes, the installation must comply
with national codes and all authorities having jurisdiction.
B
24.25”
.56”
.56”
20”
3”
23.8”
.56”
Combustion
Air Inlet
2” Diameter
Vent Connection
Outlet
B
DURING INSTALLATION,
DOORS MUST REMAIN ON
FURNACE WHEN MOVING
OR LIFTING.
Vent Connection
Outlet
Application
Upflow
Downflow
Horizontal
Top
1" 0" 0" 
Vent
0" 0" 0" 
Rear
0" 0" 0" 
Side
0" 0" 1" 
Front*
0" 0" 0" 
Floor
Combustible
Combustible
1
1. For combustible floors only when used with special 
sub-base.
Combustible
Closet
Yes
Yes
Yes
Line Contact
No
No
Yes
Cabinet Size 
A (in) 
B (in) 
All 'B' Cabinet Furnaces 
17-1/2" 
16-3/8" 
All 'C' Cabinet Furnaces 
21" 
19-7/8" 
All 'D' Cabinet Furnaces 
24-1/2" 
23-3/8" 
QUICK REFERENCE GUIDE
96%TWO STAGE MULTI-POSITION RESIDENTAL 
GAS FURNACES (33” TALL)
Subject to change without notice. Printed in U.S.A.
438336-URG-A-0209
Copyright © 2009 by Johnson Controls, Inc. All rights reserved.
Supersedes: Nothing
Johnson Controls Unitary Products
5005 York Drive
Norman, OK 73069
*438336*