C.  4" (102mm) Oval In-The-Wall (all parts purchase locally)
1.  Type B-1 oval pipe or B-W vent pipe
2.  Type B-1 oval elbows or B-W oval elbows
3.  Single story type B-1 or (B-W) gas vents require a baseplate and 
one pair of ceiling plate spacers.
4.  Multi-story type B-1 or (B-W) gas vents require a baseplate, one 
pair of ceiling plate spacers at the first floor ceiling and one pair 
of fire stop spacers at each successive ceiling level.
Stud space around gas vents must be free of obstructions and building 
paper.
4” ROUND
VENT
ENCLOSURE
ADAPTER
BASEPLATE
WALL
SIDE
FRONT
A.
4” B-1 OVAL
BRACKET
BASEPLATE
B.
4” B-1 OVAL
4” B-1 OVAL
SPACER
BASEPLATE
BASEPLATE
C.
SPACER
C.
4” 45 DEG.
OVAL ELBOWS
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment or 
accessories and repair and servicing of equipment shall be performed 
only  by  a  qualified  agency.  The  term  "qualified  agency"  means  any 
individual, firm, corporation or company which either in person or through 
a representative is engaged in and is responsible for (a) the installation 
or replacement of gas piping or (b) the connection, installation, repair or 
servicing of equipment, who is experienced in such work, familiar with 
all precautions required and has complied with all the requirements of 
the authority having jurisdiction.
The installation must conform with local codes or, in the absence of local 
codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54* Natural 
and Propane Installation Code, CSA B149.1.
*Available  from  the American  National  Standards  Institute,  Inc.,  11  West  42nd  St.,  New 
York, N.Y. 10036.
Clearances
  1. In selecting a location for installation, it is necessary to provide adequate 
accessibility clearances for servicing and proper installation.
  2. The FAW-40 can be attached to the wall or recessed into the wall up 
to 9 1/2 inches (24.1cm) in depth. 
Note: Do not place combustible 
header  or  material  on  top  of  unit  when  installed  in  wall. 
Maintain 3/4" minimum spacing above heater.
  3. The wall in which the furnace is recessed has (0) zero (0mm) clearance 
to the furnace sides. 
  4. When using side discharge registers, SOR-1 or SOK-1, the furnace 
cannot be recessed into the wall.
  5. Clearance to sidewall or combustible material is 4 inches (10.2cm).
  6. Ceiling clearance is 4 inches (10.2cm).
  7. Floor and rear wall clearance is (0) zero inches (0mm).
  8. Clearance  of  18  inches  (46cm)  is  required  to  adjacent  wall  or 
combustible material when flush mounted SOR-1, side outlet register 
is used. 
Before Installing Consider The Following Venting
  1. A chimney for residential-type or low-heat gas utilization equipment 
shall extend at least 3 feet (914mm) above the highest point where it 
passes through a roof of a building and at least 2 feet (610mm) higher 
than any portion of building within a horizontal distance of 10 feet 
(3m).
  2. This  furnace  must  not  be  connected  to  a  chimney  flue  serving  a 
separate solid-fuel burning appliance.
  3. Uninsulated Single-Wall Metal Pipe shall not be used outdoors 
in cold climates for venting gas utilization equipment.
  4. Attention! This Fan Type Vented Wall Furnace is equipped with a 
vent safety switch. In the event of spillage of flue products due to 
improper venting the vent safety switch will open, which results in 
the main burners to "shut off".
Model No. FAW-40 may be vented as shown in Figure 4. The vent cap 
termination must be at least 12 feet (3.7m) above the floor and must 
exhaust to the outdoors.. Clearance to combustible construction is held 
by the fixed spacers at 1 inch (25mm) with B-1 or (B-W) vent pipe. 
Installation must conform to local codes.
A.  4" (102mm) Round (all parts purchase locally except Item 2)
1.  Type B-1 round pipe
2.  Part No. DV-648, 4" (102mm) oval-to-round flue adapter kit (see 
accessories)
3.  Single story type B-1 gas vents require a baseplate and one pair 
of ceiling plate spacers.
4.  Multi-story type B-1 gas vents require a baseplate, one pair of 
ceiling plate spacers at the first floor ceiling and one pair of fire 
stop spacers at each successive ceiling level.
B.  4" (102mm) Oval (all parts purchase locally)
1.  Type B-1 oval pipe or B-W vent pipe
2.  Single story type B-1 or (B-W) gas vents require a baseplate and 
one pair of ceiling plate spacers.
3.  Multi-story type B-1 or (B-W) gas vents require a baseplate, one 
pair of ceiling plate spacers at the first floor ceiling and one pair 
of fire stop spacers at each successive ceiling level.
Figure 4